Xpanded, Eating, Cont – Goodman Mfg GPH13M User Manual
Page 31: Roduct, Pecifications

P
roduct
S
PecificationS
P
roduct
S
PecificationS
SS-GPH13M
www.goodmanmfg.com
31
e
xpAnded
h
eAting
d
AtA
(
Cont
.)
GPH1348M41A*
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
57.2
54.1
51.0
47.6
45.5
44.1
41.0
37.8
32.8
30.2
27.8
26.3
25.3
22.7
20.1
17.6
15.0
12.3
T/R
30.8
29.1
27.4
25.6
24.5
23.7
22.0
20.3
17.6
16.3
15.0
14.2
13.6
12.2
10.8
9.5
8.1
6.6
kW
3.90
3.83
3.75
3.68
3.63
3.60
3.53
3.46
2.48
2.43
2.38
2.36
2.34
2.29
2.24
2.19
2.14
2.09
Amps
19.0
17.7
16.7
15.8
15.3
15.0
14.3
13.7
13.1
12.6
12.1
11.9
11.8
11.2
10.6
10.1
9.5
8.7
COP
4.29
4.14
3.97
3.79
3.66
3.58
3.39
3.20
3.86
3.64
3.42
3.27
3.17
2.91
2.63
2.35
2.05
1.72
EER
14.7
14.1
13.6
13.0
12.5
12.2
11.6
10.9
13.2
12.4
11.7
11.2
10.8
9.9
9.0
8.0
7.0
5.9
Hi Pr
372
357
343
328
320
314
302
290
278
265
255
249
244
235
226
217
209
202
Lo Pr
130
121
113
104
98
95
87
77
70
62
55
51
49
42
36
30
26
21
GPH1348M41C*
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
61.8
58.5
55.1
51.5
49.2
47.7
44.3
40.8
34.5
31.9
29.3
27.7
26.7
23.9
21.2
18.5
15.8
12.9
T/R
33.8
32.0
30.1
28.2
26.9
26.1
24.2
22.3
18.9
17.4
16.0
15.2
14.6
13.1
11.6
10.1
8.6
7.1
KW
4.12
4.04
3.96
3.88
3.83
3.80
3.72
3.64
3.40
3.33
3.25
3.21
3.18
3.10
3.02
2.95
2.87
2.80
AMPS
20.1
18.8
17.7
16.7
16.2
15.9
15.1
14.4
13.8
13.3
12.7
12.4
12.3
11.7
11.1
10.5
9.8
9.0
COP
4.39
4.24
4.07
3.89
3.76
3.67
3.48
3.28
2.97
2.80
2.64
2.53
2.46
2.26
2.05
1.84
1.61
1.35
EER
15.0
14.5
13.9
13.3
12.8
12.6
11.9
11.2
10.1
9.6
9.0
8.6
8.4
7.7
7.0
6.3
5.5
4.6
HI PR
418
401
385
368
360
353
339
326
312
298
286
279
274
264
254
243
235
226
LO PR
135
125
117
107
102
98
90
80
72
64
57
53
51
43
37
31
27
21
GPH1360M41A*
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
69.8
66.0
62.2
58.1
55.5
53.8
50.0
46.1
39.1
36.1
33.3
31.4
30.3
27.1
24.1
21.0
17.9
14.7
T/R
35.9
34.0
32.0
29.9
28.5
27.7
25.7
23.7
20.1
18.6
17.1
16.2
15.6
14.0
12.4
10.8
9.2
7.5
kW
4.80
4.71
4.62
4.53
4.47
4.44
4.35
4.26
2.41
2.36
2.32
2.30
2.28
2.24
2.20
2.16
2.12
2.08
Amps
24.1
22.5
21.2
20.1
19.4
19.1
18.1
17.3
16.7
16.0
15.4
15.0
14.9
14.2
13.4
12.8
12.0
11.0
COP
4.25
4.10
3.94
3.76
3.63
3.55
3.36
3.17
4.76
4.47
4.19
4.00
3.88
3.54
3.20
2.84
2.47
2.06
EER
14.5
14.0
13.5
12.8
12.4
12.1
11.5
10.8
16.3
15.3
14.3
13.7
13.2
12.1
10.9
9.7
8.4
7.1
Hi Pr
385
369
354
339
331
325
312
300
287
274
263
257
252
243
233
224
216
208
Lo Pr
134
124
116
107
101
97
89
80
72
64
56
52
50
43
37
31
27
21
GPH1360M41C*
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
72.2
68.4
64.3
60.1
57.4
55.7
51.7
47.7
39.8
36.7
33.8
31.9
30.7
27.6
24.5
21.3
18.2
14.9
T/R
37.5
35.5
33.5
31.3
29.9
28.9
26.9
24.8
20.7
19.1
17.6
16.6
16.0
14.3
12.7
11.1
9.5
7.8
KW
4.98
4.88
4.78
4.67
4.62
4.57
4.48
4.38
4.20
4.10
4.01
3.95
3.91
3.81
3.71
3.62
3.52
3.42
AMPS
25.4
23.7
22.3
21.1
20.4
20.1
19.0
18.2
17.5
16.8
16.1
15.8
15.6
14.9
14.1
13.4
12.5
11.5
COP
4.25
4.10
3.94
3.77
3.64
3.56
3.38
3.19
2.77
2.62
2.47
2.37
2.30
2.12
1.93
1.73
1.51
1.28
EER
14.5
14.0
13.5
12.9
12.4
12.2
11.5
10.9
9.5
9.0
8.4
8.1
7.9
7.2
6.6
5.9
5.2
4.4
HI PR
421
404
388
371
362
355
342
328
314
300
288
281
276
266
255
245
236
228
LO PR
134
124
116
107
101
97
89
79
72
64
56
52
50
43
37
31
27
21
Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed.
Amps: Unit amps (comp.+ evap motor + condenser fan motor)
High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting.
kW = Total system power