Heat kit electrical data, Lectrical, Roduct – Goodman Mfg GPH13M User Manual
Page 35: Pecifications, Lower

P
roduct
S
PecificationS
P
roduct
S
PecificationS
SS-GPH13M
www.goodmanmfg.com
35
h
eAt
k
it
e
leCtRiCAl
d
AtA
(B
loweR
o
nly
, h
eAt
m
ode
)
Model and
Heat Kit Usage
Circuit #1
Circuit #2
Single-Point Kit
Actual kW /
BTU@ 240V
MCA¹
MOP²
MCA¹
MOP²
MCA¹
MOP²
GPH1324M41**
1.9
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
44
50
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
55
60
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
68
70
9.5 / 32,400
GPH1330M41**
1.9
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
48
50
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
59
60
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
72
80
9.5 / 32,400
HKP-15C*
43 / 49
45 / 50
21 / 25
25 / 25
97
100
14.25 / 48,600
GPH1336M41**
1.9
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
50
60
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
62
70
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
75
80
9.5 / 32,400
HKP-15C*
43 / 49
45 / 50
21 / 25
25 / 25
100
100
14.25 / 48,600
GPH1342M41**
3.6
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
52
60
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
63
70
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
76
80
9.5 / 32,400
HKP-15C*
43 / 49
45 / 50
21 / 25
25 / 25
101
110
14.25 / 48,600
GPH1348M41**
7.3
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
59
70
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
71
80
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
84
90
9.5 / 32,400
HKP-15C*
43 / 49
45 / 50
21 / 25
25 / 25
109
110
14.25 / 48,600
HKP-20C*
43 / 49
45 / 50
43 / 49
45 / 50
136
150
19.0 / 64,800
GPH1360M41**
9.5
---
---
---
--
--
---
HKR-05*, HKR-05C*
21 / 25
25 / 25
---
---
67
80
4.75 / 16,200
HKR-08*, HKR-08C*
32 / 36
35 / 40
---
---
78
90
7.0 / 23,800
HKR-10*, HKR-10C*
43 / 49
45 / 50
---
---
91
100
9.5 / 32,400
HKP-15C*
43 / 49
45 / 50
21 / 25
25 / 25
116
125
14.25 / 48,600
HKP-20C*
43 / 49
45 / 50
43 / 49
45 / 50
144
150
19.0 / 64,800
¹ Minimum Circuit Ampacity @ 208 / 240 V
² Maximum Overcurrent Protection Device @ 208 / 240 V
* Revision level that may or may not be designated
C Circuit breaker option
^ Heat Kit requires three-phase power supply
Note: HKP-15C* and HKP-20C* replace HKR-15C and HKR-20C respectively to meet new UL1995 requirements.