beautypg.com

Expanded heating data, Xpanded, Eating – Goodman Mfg GPH13M User Manual

Page 29: Roduct, Pecifications

background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-GPH13M

www.goodmanmfg.com

29

e

xpAnded

h

eAting

d

AtA

GPH1324M41A*

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

28.9

27.4

25.8

24.1

23.0

22.3

20.7

19.1

16.7

15.4

14.2

13.4

12.9

11.6

10.3

9.0

7.6

6.3

T/R

32.4

30.7

28.9

27.0

25.8

25.0

23.2

21.4

18.8

17.3

15.9

15.1

14.5

13.0

11.5

10.1

8.6

7.0

kW

2.14

2.10

2.06

2.01

1.99

1.97

1.94

1.89

2.32

2.26

2.21

2.18

2.16

2.10

2.05

2.00

1.95

1.89

Amps

10.4

9.8

9.2

8.8

8.5

8.4

8.0

7.7

7.4

7.1

6.9

6.7

6.7

6.4

6.1

5.8

5.5

5.1

COP

3.96

3.82

3.67

3.50

3.38

3.30

3.13

2.95

2.11

1.99

1.88

1.80

1.75

1.61

1.47

1.31

1.15

0.97

EER

13.5

13.1

12.5

12.0

11.5

11.3

10.7

10.1

7.2

6.8

6.4

6.2

6.0

5.5

5.0

4.5

3.9

3.3

Hi Pr

379

364

350

334

326

320

308

295

283

270

260

253

249

239

230

221

213

205

Lo Pr

135

126

118

108

102

98

90

80

73

65

57

53

51

43

37

31

27

22

GPH1324M41C*

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

31.3

29.6

27.8

26.0

24.9

24.1

22.4

20.6

17.2

15.9

14.6

13.8

13.3

11.9

10.6

9.2

7.9

6.5

T/R

32.6

30.9

29.1

27.2

26.0

25.2

23.4

21.5

18.0

16.6

15.3

14.4

13.9

12.5

11.1

9.6

8.2

6.7

kW

2.11

2.07

2.03

1.99

1.97

1.95

1.92

1.88

1.93

1.89

1.85

1.82

1.81

1.77

1.73

1.69

1.65

1.61

Amps

10.4

9.8

9.3

8.8

8.5

8.4

8.0

7.7

7.4

7.2

6.9

6.8

6.7

6.5

6.1

5.9

5.6

5.2

COP

4.34

4.19

4.01

3.82

3.69

3.61

3.42

3.22

2.61

2.46

2.32

2.22

2.15

1.98

1.79

1.60

1.40

1.18

EER

14.8

14.3

13.7

13.1

12.6

12.3

11.7

11.0

8.9

8.4

7.9

7.6

7.4

6.8

6.1

5.5

4.8

4.0

Hi Pr

377

361

347

332

324

318

306

293

281

268

258

252

247

238

229

219

211

204

Lo Pr

146

135

127

116

110

106

97

87

78

70

61

57

55

46

40

34

30

23

GPH1330M41A*

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

36.2

34.3

32.3

30.2

28.8

27.9

25.9

23.9

21.2

19.6

18.0

17.0

16.4

14.7

13.0

11.4

9.7

7.9

T/R

31.9

30.2

28.4

26.6

25.4

24.6

22.9

21.1

18.7

17.3

15.9

15.0

14.4

13.0

11.5

10.0

8.6

7.0

kW

2.74

2.68

2.63

2.58

2.55

2.53

2.48

2.43

2.29

2.24

2.19

2.17

2.15

2.10

2.05

2.00

1.95

1.90

Amps

13.6

12.7

12.0

11.4

11.1

10.9

10.4

9.9

9.6

9.2

8.9

8.7

8.6

8.2

7.8

7.5

7.0

6.5

COP

3.87

3.74

3.59

3.42

3.30

3.23

3.06

2.88

2.71

2.55

2.40

2.30

2.23

2.05

1.86

1.66

1.46

1.22

EER

13.2

12.8

12.3

11.7

11.3

11.0

10.5

9.8

9.2

8.7

8.2

7.9

7.6

7.0

6.4

5.7

5.0

4.2

Hi Pr

375

359

346

330

323

316

304

292

280

267

256

250

246

236

227

218

210

203

Lo Pr

131

122

114

105

99

95

88

78

70

63

55

51

49

42

36

30

27

21

GPH1330M41C*

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

34.1

32.2

30.3

28.4

27.1

26.2

24.4

22.5

19.9

18.4

16.9

16.0

15.4

13.8

12.2

10.7

9.1

7.5

T/R

28.8

27.3

25.7

24.0

22.9

22.2

20.7

19.0

16.9

15.6

14.3

13.5

13.0

11.7

10.4

9.0

7.7

6.3

KW

2.38

2.34

2.29

2.25

2.22

2.21

2.16

2.12

2.21

2.16

2.12

2.09

2.07

2.02

1.98

1.93

1.89

1.84

AMPS

11.9

11.1

10.6

10.0

9.8

9.6

9.2

8.8

8.5

8.2

7.9

7.8

7.7

7.4

7.1

6.8

6.4

6.0

COP

4.19

4.04

3.87

3.69

3.56

3.48

3.30

3.10

2.64

2.49

2.34

2.24

2.18

2.00

1.81

1.62

1.41

1.19

EER

14.3

13.8

13.2

12.6

12.2

11.9

11.3

10.6

9.0

8.5

8.0

7.7

7.4

6.8

6.2

5.5

4.8

4.1

HI PR

355

341

328

313

306

300

288

277

265

253

243

237

233

224

216

207

199

192

LO PR

133

124

116

106

100

97

89

79

71

64

56

52

50

42

37

31

27

21

Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed.

Amps: Unit amps (comp.+ evap motor + condenser fan motor)

High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting.

kW = Total system power