-10-
G0463 Small Mill/Drill
Figure 2. A 5-15 plug and receptacle.
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro-
cess. DO NOT connect the machine to the
power source until instructed to do so.
110V Operation
Amperage Draw
The Model G0463 motor draws the following
amps under maximum load:
Motor Draw ..............................................7 Amps
Circuit Recommendations
We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit breaker size given below. Never replace a
circuit breaker with one of higher amperage with-
out consulting a qualified electrician to ensure
compliance with wiring codes.
If you are unsure
about the wiring codes in your area or you
plan to connect your machine to a shared cir-
cuit, you may create a fire hazard—consult a
qualified electrician to reduce this risk.
Circuit Breaker .......................................10 Amps
Plug/Receptacle Type
Included Plug Type ........................... NEMA 5-15
This machine must have a ground prong in
the plug to help ensure that it is grounded.
DO NOT remove ground prong from plug
to fit into a two-pronged outlet! If the plug
will not fit the outlet, have the proper outlet
installed by a qualified electrician.
Extension Cords
We do not recommend the use of extension
cords, if you find it absolutely necessary:
•
Use at least a 16 gauge cord that does not
exceed 50 feet in length!
•
The extension cord must also contain a
ground wire and plug pin.
•
A qualified electrician MUST size cords over
50 feet long to prevent motor damage.
SECTION 2: CIRCUIT REQUIREMENTS
Electrocution or fire could
result if this machine is
not grounded correctly or
if your electrical configu-
ration does not comply
with local and state codes.
Ensure compliance by
checking with a qualified
electrician!