Cpg060*3d (t, Iring, Iagram – Goodman Mfg SS-CPG36-72 User Manual

Page 37: Roduct, Pecifications, Hree, Hase, Irect, Rive, Arnin g

background image

36

www.goodmanmfg.com

SS-CPG36-72

SS-CPG36-72

www.goodmanmfg.com

37

P

roduct

S

PecificationS

P

roduct

S

PecificationS

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

w

arnin

G

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.

w

irinG

d

iaGram

CPG060*3d (t

hree

-P

hase

, d

ireCt

d

rive

)

COOLING SPEED (YELLOW WIRE)

USE NEC CLASS 2 WIRE.

5. USE COPPER CONDUCTORS ONLY.

6. L1 AND L2 ON ICC CONTROL IS 24V INPUT.

7. SPEED TAP TERMINATIONS SHOWN ON

DIAGRAM ARE REPRESENTATIVE, BUT

ACTUAL FACTORY SETTINGS MAY BE

DIFFERENT BASED ON THE HEATING VALUE

OF THE UNIT.

3. FOR DIFFERENT THAN FACTORY SPEED TAP.

CHANGE COOLING SPEED AT MOTOR T3 AND

T4 TERMINALS. CHANGE HEATING SPEED AT

MOTOR T1. T2, AND T5 TERMINALS

4. ACCESSORY ECONOMIZER PLUG ADJACENT

TO BLOWER HOUSING IN RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND

ATTACH FEMALE PLUG TO ECONOMIZER

ACCESSORY.

1. REPLACEMENT WIRE MUST BE THE SAME

SIZE AND TYPE OF INSULATION AS ORIGINAL.

(USE COPPER CONDUCTOR ONLY).

AUXILIARY LIMIT SWITCH

FEMALE PLUG/CONNECTOR

INTEGRATED IGNITION CONTROL

LS

4

INSTALLER/SERVICEMAN

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

STATUS LIGHT

3 BLINKS

6 BLINKS

2 BLINKS

4 BLINKS
5 BLINKS

OFF

ON

1 BLINK

OPEN AUX. LIMIT

FALSE FLAME SENSED

OUTPUT DELAY

OPEN LIMIT SWITCH

COMPRESSOR

WITHOUT INDUCER ON

PRESSURE SWITCH CLOSED

PRESSURE SWITCH

SWITCH

OPEN

OPEN ROLLOUT

SWITCH

IGNITION FAILURE

NORMAL OPERATION

NO POWER OR

INTERNAL CONTROL

EQUIP. STATUS

OR

OR

FAULT

TO THERMOSTAT

TERMINAL BLOCK

G

R

5

7

9

ECON

IIC

Y1

W

Y2

3

6

12

1

0

8

11

RS

ALS

PS

BAD SWITCH

AUX. LIMIT OPEN

ANTI-CYCLE TIMER

STICKING GAS VALVE

BAD SWITCH

3 MIN. COMP.

PRESSURE SWITCH

PRESSURE SWITCH

CHECK

CHECK

GAS PRESSURE

FLAME ROLLOUT

FLAME SENSOR

GAS VALVE

CHECK FUSE ON CONTROL

CHECK INPUT POWER

REPLACE CONTROL

GAS FLOW

CHECK

-

PLF

C

NOTE 4

4

3 2 1

5

6

GV

C

T3 - LOW SPEED

T4 - HIGH SPEED

IGN

NOTE 6

L1

F

D1

FS

TR

L1

240/3/60

SUPPLY VOLTAGE

CM

CONDENSER MOTOR

NOTE 6

FS

IIC

L2

VM

1

VMR

L3

LS

LIMIT SWITCH

VENT MOTOR RELAY

VENT MOTOR

PRESSURE SWITCH

TERMINAL BLOCK (24V SIGNAL)

ROLLOUT SWITCH

VMR

VM

PS

PLF

TB1

RS

NOTES

FAN CAPACITOR

CONTACTOR

GAS VALVE

IGNITOR

EQUIPMENT GROUND

FLAME SENSOR

EVAPORATOR MOTOR

FC

FUSE

F

C

GV

FS

GND

IGN

IIC

EM

L2

L3

COMPRESSOR

COMPONENT LEGEND

COMP

ALS

HEATING SPEED (WHITE WIRE)

T5 - HIGH SPEED (140)

T2 - MED. SPEED

T1 - LOW SPEED (070)

TB1

GND

YL

BK

BK

POWER SUPPLY
240/3/60

RD

WH

BL

BREA
K

FO

R T
W

O

ST

AG

E

T2

CO
MP
RES
SO

R

IIC

FC

RD

RD

L2

C

T2

T3

L3

L1

T1

BK

BK

PU

YL

T3 T2 T1

COMP

BK

PU

CM

BR

PK

VMR

C22

OR

SP

EE

D-U

P

M

O

UN

T

T1

P2

REQU

IR

ED

SCR

EW

P3

135
120

150

FUSE

3

AM

P M

AX

F1

WH

YL

RD

RD

11

8

12

9

7

10

4

2

5
6

3

1

FS

RD

BR

NOTE 6

SEE

COOL

DI

L1

HE

AT

UNUSE

D

L2

BL

WH

YL

YL

PU

RD

BL

RD

PU

WH

GR BL

BL

BL

P1

ECON

RD

ALS

GR

PS

RS

PLF

YL

YL

NOTE 4

GAS VALVE

MV

2

1 4

5

YL

BL

W. R.

GAS VALVE

PU

(ALT.) HONEYWELL

3 6

YL

BR

WH

BL

YL

PU

PU

PU

WH

BR

R

G

Y1 W

OR

RD

TO THERMOSTAT

C

MV

FS

IGN

VM

BL

BL

YL

WH

BR

BL

BK

GV

GV

BK

FOR

SMOKE/

FIRE

DETECTOR

REPLACE

JUMPER

TB1

TB1

TB1

TR

TRANSFORMER

EM

L

3

1

2

N

SEE NOTE 2

L2

C

CM

T3

COMP

T3

T2

FC

L1

C T1

T1

C

T2

PU

BL

230/3/60 0140L02106-A

YL

LPS

HPS

YL/PK

BL/PK

HPS

LPS

HPS

HIGH PRESSURE SWITCH

GR

VMR

TB1

5

4

EM

1

3

2

C

H

NOTE 3

BL

HIGH VOLTAGE

FACTORY WIRING

LOW VOLTAGE

FIELD WIRING

LINE VOLTAGE

LOW VOLTAGE

TB1

WH
YL

NOTE 3 & 7

1

5

RD

S1

S2

Y2

YL

BL

RD

Y1

Y/Y2

YL

W

Y/Y2

BL

G

R

W

NO ECONOMIZER

G

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH
GR

C

R

YL

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT

FIELD WIRING

BL

C

2 STAGE COOLING

TB1

G
R

W

Y
C

TB1

TB1

Y

W

R

G

C

W

Y2

G
R

C

Y

1

STAT

STAT

STAT

3

2

1

RD

RD

LS

208

TR

BL

24V

C

BL

PK

240

BK

RD

BK

BL

NOTE 2

RD

BL/PK BLUE WITH PINK STRIP

YL/PK YELLOW WITH PINK STRIP

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

BL

G

T4

EM

L

T3

T2

T1

C

GR

RD

BK

N

T5

GR

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF

OVER CURRENT PROTECTION

8. FOR LOW STAGE OPERATION ONLY, REMOVE

WHITE JUMPER. FOR 2 STAGE OPERATION,

REMOVE JUMPER AND CONNECT W2 TO W2

ON THERMOSTAT.

BR

W2

BR

NOTE 8

SEE

WH

YL

BR

PU

OR

3

1

2

OR

OR

WH

SEE NOTE 5

W2

3

YL

MAIN LIMIT OPEN

LPS

LOW PRESSURE SWITCH

2. FOR 208 VOLT TRANSFORMER OPERATION

MOVE BLACK WIRES FROM TERMINAL 3 TO

TERMINAL 2 ON TRANSFORMER.

C

YL

RD