Cpg060*3d (t, Iring, Iagram – Goodman Mfg SS-CPG36-72 User Manual
Page 37: Roduct, Pecifications, Hree, Hase, Irect, Rive, Arnin g

36
www.goodmanmfg.com
SS-CPG36-72
SS-CPG36-72
www.goodmanmfg.com
37
P
roduct
S
PecificationS
P
roduct
S
PecificationS
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
⚠
w
arnin
G
High
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.
⚡
w
irinG
d
iaGram
—
CPG060*3d (t
hree
-P
hase
, d
ireCt
d
rive
)
COOLING SPEED (YELLOW WIRE)
USE NEC CLASS 2 WIRE.
5. USE COPPER CONDUCTORS ONLY.
6. L1 AND L2 ON ICC CONTROL IS 24V INPUT.
7. SPEED TAP TERMINATIONS SHOWN ON
DIAGRAM ARE REPRESENTATIVE, BUT
ACTUAL FACTORY SETTINGS MAY BE
DIFFERENT BASED ON THE HEATING VALUE
OF THE UNIT.
3. FOR DIFFERENT THAN FACTORY SPEED TAP.
CHANGE COOLING SPEED AT MOTOR T3 AND
T4 TERMINALS. CHANGE HEATING SPEED AT
MOTOR T1. T2, AND T5 TERMINALS
4. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS
4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCH CLOSED
PRESSURE SWITCH
SWITCH
OPEN
OPEN ROLLOUT
SWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
TO THERMOSTAT
TERMINAL BLOCK
G
R
5
7
9
ECON
IIC
Y1
W
Y2
3
6
12
1
0
8
11
RS
ALS
PS
BAD SWITCH
AUX. LIMIT OPEN
ANTI-CYCLE TIMER
STICKING GAS VALVE
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUT
FLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROL
CHECK INPUT POWER
REPLACE CONTROL
GAS FLOW
CHECK
-
PLF
C
NOTE 4
4
3 2 1
5
6
GV
C
T3 - LOW SPEED
T4 - HIGH SPEED
IGN
NOTE 6
L1
F
D1
FS
TR
L1
240/3/60
SUPPLY VOLTAGE
CM
CONDENSER MOTOR
NOTE 6
FS
IIC
L2
VM
1
VMR
L3
LS
LIMIT SWITCH
VENT MOTOR RELAY
VENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
ROLLOUT SWITCH
VMR
VM
PS
PLF
TB1
RS
NOTES
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUND
FLAME SENSOR
EVAPORATOR MOTOR
FC
FUSE
F
C
GV
FS
GND
IGN
IIC
EM
L2
L3
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
HEATING SPEED (WHITE WIRE)
T5 - HIGH SPEED (140)
T2 - MED. SPEED
T1 - LOW SPEED (070)
TB1
GND
YL
BK
BK
POWER SUPPLY
240/3/60
RD
WH
BL
BREA
K
FO
R T
W
O
ST
AG
E
T2
CO
MP
RES
SO
R
IIC
FC
RD
RD
L2
C
T2
T3
L3
L1
T1
BK
BK
PU
YL
T3 T2 T1
COMP
BK
PU
CM
BR
PK
VMR
C22
OR
SP
EE
D-U
P
M
O
UN
T
T1
P2
REQU
IR
ED
SCR
EW
P3
135
120
150
FUSE
3
AM
P M
AX
F1
WH
YL
RD
RD
11
8
12
9
7
10
4
2
5
6
3
1
FS
RD
BR
NOTE 6
SEE
COOL
DI
L1
HE
AT
UNUSE
D
L2
BL
WH
YL
YL
PU
RD
BL
RD
PU
WH
GR BL
BL
BL
P1
ECON
RD
ALS
GR
PS
RS
PLF
YL
YL
NOTE 4
GAS VALVE
MV
2
1 4
5
YL
BL
W. R.
GAS VALVE
PU
(ALT.) HONEYWELL
3 6
YL
BR
WH
BL
YL
PU
PU
PU
WH
BR
R
G
Y1 W
OR
RD
TO THERMOSTAT
C
MV
FS
IGN
VM
BL
BL
YL
WH
BR
BL
BK
GV
GV
BK
FOR
SMOKE/
FIRE
DETECTOR
REPLACE
JUMPER
TB1
TB1
TB1
TR
TRANSFORMER
EM
L
3
1
2
N
SEE NOTE 2
L2
C
CM
T3
COMP
T3
T2
FC
L1
C T1
T1
C
T2
PU
BL
230/3/60 0140L02106-A
YL
LPS
HPS
YL/PK
BL/PK
HPS
LPS
HPS
HIGH PRESSURE SWITCH
GR
VMR
TB1
5
4
EM
1
3
2
C
H
NOTE 3
BL
HIGH VOLTAGE
FACTORY WIRING
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
TB1
WH
YL
NOTE 3 & 7
1
5
RD
S1
S2
Y2
YL
BL
RD
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
W
NO ECONOMIZER
G
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
2 STAGE COOLING
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y
1
STAT
STAT
STAT
3
2
1
RD
RD
LS
208
TR
BL
24V
C
BL
PK
240
BK
RD
BK
BL
NOTE 2
RD
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
BL
G
T4
EM
L
T3
T2
T1
C
GR
RD
BK
N
T5
GR
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF
OVER CURRENT PROTECTION
8. FOR LOW STAGE OPERATION ONLY, REMOVE
WHITE JUMPER. FOR 2 STAGE OPERATION,
REMOVE JUMPER AND CONNECT W2 TO W2
ON THERMOSTAT.
BR
W2
BR
NOTE 8
SEE
WH
YL
BR
PU
OR
3
1
2
OR
OR
WH
SEE NOTE 5
W2
3
YL
MAIN LIMIT OPEN
LPS
LOW PRESSURE SWITCH
2. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
C
YL
RD