G0583 1 HP Canister Dust Collector

-23-

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Motor will not start, or it
growls on start up.

1. Power supply fuse or circuit

breaker has tripped.

2. Toggle switch is broken inside.

3. Start capacitor is at fault.
4. Motor fan cover is dented, stopping

the fan from being able to spin.

5. Motor is at fault.

1. Disconnect power, and inspect circuit for electrical

shorts and repair. Replace circuit breaker if it is
old or has tripped many times.

2. Disconnect power, and use an ohmmeter to check

switch terminals for continuity, and replace switch
if required.

3. Replace start capacitor.
4. Replace motor fan cover (and fan, if damaged).

5. Replace motor.

Motor runs slower than
normal.

1. Poor electrical connection.

2. Low power source voltage.

3. Motor is at fault.

1. Inspect the power supply for loose, corroded, or

overheated electrical connections and repair.

2. Have the power source voltage checked; reduce

the length of extension cord.

3. Replace the motor.

Loud, repetitious noise, or
excessive vibration coming
from dust collector.

1. Dust collector is not on a flat

surface and wobbles.

2. Impeller fan is damaged and

unbalanced.

3. The motor mounting is loose.

4. Impeller is loose on the motor

shaft.

5. Motor fan cover is dented, causing

the motor fan to hit the cover
while spinning.

1. Stabilize the dust collector.

2. Unplug dust collector, and inspect the impeller for

dents, bends, loose fins. Replace impeller if any
damage is found.

3. Make sure all fasteners on the dust collector are

tight.

4. Replace the motor and impeller as a set if the

motor shaft and the impeller hub is damaged.

5. Replace motor fan cover.

Dust collector does not
adequately collect dust or
chips; poor performance.

1. Dust collection bag is full.
2. There is a restriction at the inlet

grate.

3. The dust collector is too far away

from the point of suction, or there
are too many sharp bends in the
ducting.

4. The lumber is wet and not flowing

through the dust lines smoothly.

5. There is a leak in the ducting, or a

series of small leaks, or too many
open ports.

6. There is a restriction in the

ducting, or the ducting and ports
are incorrectly sized.

7. The machine dust collection design

is inadequate.

8. The dust collector is too small for

the dust collection system.

1. Empty bags.
2. Remove dust line from dust collector inlet and

clean debris from the inlet grate (and wire-
connector, if installed).

3. Relocate the dust collector closer to the point of

suction, and rework ducting without sharp bends.
Refer to the Dust Collection Basics handbook (ISBN
0-9635821-2-7) to help configure your dust system.

4. Process lumber with less than 20% moisture

content.

5. Rework the ducting as to eliminate all leaks, and

refer to the Dust Collection Basics handbook (ISBN
0-9635821-2-7) for more solutions.

6. Rework the ducting as to eliminate all restrictions,

and refer to the Dust Collection Basics handbook
(ISBN 0-9635821-2-7) for more solutions.

7. Ask your dealer for proper dust collection

accessories or the SHOP FOX

®

Dust Collection

Nozzle on Stand.

8. Install a larger dust collector to power your dust

collection system.