Canister filter – Grizzly G0583 User Manual
Page 16
-14-
G0583 1 HP Canister Dust Collector
Components and Hardware Needed:
QTY
Canister Filter .....................................................1
Handle ................................................................1
Metal Canister Clamp .........................................1
Narrow Foam Strip .............................................1
Tools Needed:
Hex Wrench 3mm ...............................................1
To install the canister:
1. Secure the narrow foam strip around the
outside top rim of the collector as shown in
Figure 9.
Figure 9. Narrow foam strip.
2. Trim the excess foam strip so the ends come
together evenly as shown in
Figure 9.
Canister Filter
Figure 10. Installing canister handle.
Figure 11. Installed and secured canister filter.
4. Place the canister on top of the collector.
5. Position the metal canister clamp around the
bottom of the canister filter, so it will com-
press around the foam strip (
Figure 11), and
latch the clamp closed.
3. Install the handle onto the top of the canister
and tighten the set screw against the flat of
the shaft (
Figure 10).
Shaft Flat