G0583 1 HP Canister Dust Collector

Be sure that you extend the bare copper wire
down all branches of the system. Do not forget
to connect the wires to each other with wire nuts
when two branches meet at a “Y” or “T” connec-
tion.

Ensure that the entire system is grounded. If
using plastic blast gates to direct air flow, the
grounding wire must be jumped (

Figure 14)

around the blast gate without interruption to the
grounding system.

Figure 14. Ground jumper wire when using

plastic blast gates or elbows and metal duct.

Plastic Blast Gate

Metal Duct

Copper Ground Wire

Figure 15. Flex-hose grounded to machine.

Ground Screw

Flex-Hose

Internal Ground Wire

External Ground Wire

We also recommend wrapping the outside of all
plastic ducts with bare copper wire to ground the
outside of the system against static electrical
build up. Wire connections at Y’s and T’s should
be made with wire nuts.

Attach the bare ground wire to each stationary
woodworking machine and attach the canister
dust collector frame with a ground screw as
shown in

Figure 15. Ensure that each machine is

continuously grounded to the grounding terminal
in your electric service panel.