Before you call for service – GE MONACO 6000A User Manual
Page 18
18
Before you call for service…
Customer Ser
vice
Tr
oubleshooting T
ips
Safety Instr
uctions
Customer Ser
vice
Tr
oubleshooting T
ips
Safety Instr
uctions
Customer Ser
vice
Tr
oubleshooting T
ips
Operating Instr
uctions
Safety Instr
uctions
Installation Instr
uctions
Problem
Possible Causes
What To Do
No soft water
No salt in the storage tank.
•
Refill with salt. See the Step-by-Step Installation Instructions.
Use the TOUCH HOLD button to start a regeneration. See
the About the Face Plate Timer section.
Transformer unplugged
•
Check for loss of power and correct. Reset the times, then
at the wall outlet, or power
use the TOUCH HOLD button to start a regeneration. See
cable disconnected.
the About the Face Plate Timer section.
Fuse blown, circuit breaker
•
Replace the fuse, reset the circuit breaker, or switch breaker
tripped, or circuit switched
on. Reset the times and then use the TOUCH HOLD button
off.
to start a regeneration. See the About the Face Plate Timer
section.
Timer in the vacation
•
See VACATION feature to return the softener to service.
(VAC) position.
See the About the Face Plate Timer section.
No regenerations set on
•
Select and program a schedule. See the About the Water
the timer.
Softener System
section. Use the TOUCH HOLD button to
start a regeneration. See the About the Face Plate Timer
section.
Manual bypass valve(s) in
•
Move stem in single bypass valve to SERVICE.
bypass position.
Salt in storage tank bridged.
•
See the Breaking a Salt Bridge section.
Dirty, plugged or damaged
•
Take apart and clean or replace damaged parts.
nozzle & venturi.
See Cleaning the Nozzle and Venturi Assembly section.
Valve drain hose plugged.
•
Hose must not have kinks, sharp bends or any water flow
breakage. See the Step-by-Step Installation Instructions.
Low or high system water pressure •
If pressure is low, increase to a minimum of 20 psi. Add a
(Low pressure may disrupt brine
pressure reducing valve, in the supply pipe to the softener,
draw during recharge. High
if day time pressure is over 100 psi.
pressures may cause inner valve
parts failure.)
Water hard sometimes
Too few regenerations.
•
See the Regeneration Chart, for the correct setting.
More water being used.
•
See the Regeneration Chart, for the correct setting.
Hot water used when softener
•
Avoid using hot water as the water heater refills with hard
is regenerating.
water. See the Automatic Bypass section.
Possible increase in water
•
Call GE Answer Center 800.626.2000 for a new water
hardness.
analysis.
Leaking faucet or toilet valve.
•
A small leak will waste hundreds of gallons of water in a
few days. Fix all plumbing leaks and always fully close faucets.
Troubleshooting Tips
Save time and money! Review the chart on this
page first and you may not need to call for service.