beautypg.com

Performance data sheet – GE GNSV70FBL User Manual

Page 4

background image

Performance Data Sheet.

SmartWater Filtration System GNSV70FBL and GNSV75FWW
Using Filter FQSVF

■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI 42 and 53.

■ Actual performance may vary with local water conditions.
■ Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the

system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Standard No. 42: Aesthetic Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L ± 10%

1.94 mg/L

<0.05 mg/L

<0.05 mg/L

97.41%

97.22%

>50%

T & O

Particulate**

≥ 10000 particles

4100000 #/mL

24400 #/mL

67000 #/mL

99.35%

97.84%

>85%

Standard No. 53: Health Effects

Turbidity

1 NTU***

11 ± 1 NTU***

11.08 NTU

0.21 NTU

0.38 NTU

98.04%

96.20%

0.5 NTU

Cysts

99.95% red.

Min. 50000L

141750 #/L

<1 #/L

2 #/L

>99.99%

>99.99%

>99.95%

Asbestos

99% red.

10

7

and 10

8

fibers/L;

168 MF/L

0.99885891 MF/L

<1 MF/L

99.89%

99.82%

>99%

fibers >10 µm long

Lead,

0.015 mg/L

0.15 mg/L ± 10%

0.147 mg/L

<0.001 mg/L

<0.001 mg/L

99.32%

99.29%

0.010 mg/L

pH 6.5
Lead,

0.015 mg/L

0.15 mg/L ± 10%

0.143 mg/L

<0.001 mg/L

<0.001 mg/L

99.30%

99.29%

0.010 mg/L

pH 8.5
Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.006033333 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.68%

96.49%

0.002 mg/L

pH 6.5
Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.0058 mg/L

0.000333 mg/L

0.0005 mg/L

94.34%

92.06%

0.002 mg/L

pH 8.5
Lindane

0.0002 mg/L

0.002 mg/L ± 10%

0.002016667 mg/L

<0.00002 mg/L

<0.00002 mg/L

99.00%

98.95%

0.0002 mg/L

Benzene

0.001 mg/L

0.015 mg/L ± 10%

0.01417 mg/L

0.000500 mg/L

0.000500 mg/L

96.47%

96.43%

0.005 mg/L

Atrazine

0.003 mg/L

0.009 mg/L ± 10%

0.00830 mg/L

0.002000 mg/L

0.002000 mg/L

74.82%

61.54%

0.003 mg/L

VOC Reduction

Chloroform

0.080 mg/L

0.30 ± 10%

0.31429 mg/L

0.00186429 mg/L

0.0055 mg/L

99.40%

98.28%

95%

*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units

Operating Specifications
Capacity: certified for up to 160 gallons (605 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.60 gpm (2.27 l/min)

4

Replacement Filter Canisters/Estimated Replacement Costs

FQSVF—Replacement filter canister $35–40

For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)

IOWA RESIDENTS ONLY:

Store or Seller’s Name

Address

City

State

Zip

Telephone

Seller’s signature

Customer’s signature

Date

State of California

Department of Health Services

Water Treatment Device

Certificate Number

Date Issued: February 9, 2004

1601

04 -

Trademark/Model Designation

Replacement Element(s)

GXSV65 F

FQSVF

GQSV65 F

FQSVF

GNSV70 FBL

FQSVF

GNSV75 FWW

FQSVF

Cysts
Turbidity

General Electric Company

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Atrazine
Lindane
Benzene
VOCs

Organic Contaminants

Alachlor

Atrazine

Benzene

Carbofuran

Carbon Tetrachloride

Chlorobenzene

Chloropicrin

2,4-D

DBCP

o-Dichlorobenzene

p-Dichlorobenzene

1,2-Dichloroethane

1,1-Dichloroethylene

cis-1,2-Dichloroethylene

trans-1,2-Dichloroethylene

1,2-Dichloropropane

cis-1,3-Dichloropropylene

Dinoseb

Simazine

Styrene

1,1,2,2-Tetrachloroethane

Tetrachloroethylene

Toluene

2,4,5-TP (Silvex)

Tribromoacetic Acid

1,2,4-Trichlorobenzene

1,1,1-Trichloroethane

1,1,2-Trichloroethane

Trichloroethylene

Trihalomethanes (THMs)

Bromodichloromethane

Bromoform

Chloroform

Chlorodibromomethane

Xylenes

Endrin
Ethylbenzene
EDB
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
Methoxychlor
Pentachlorophenol

160 gal

Rated Service Capacity:

0.6 gpm

Rated Service Flow:

Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Manufacturer:

Asbestos
Lead
Mercury