Valve specifications – GE Autorol 255 Valve / 400 Series User Manual
Page 27
27
260 Troubleshooting
Valve Specifications
Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-120 psi (1.38 - 8.27 bar)
Standard 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz
Optional 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . 115V 50 Hz, 230V 50 Hz,
230V 60 Hz, 100V 60 Hz, 100V 50 Hz
Operating Ambient Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 °F to 120 °F (1 °C to 49 °C)
Operating Water Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 °F to 100 °F (1 °C to 38 °C)
Problem
Possible Cause
Solution
1. No water flow
display when water
is flowing.
a. Bypass valve in bypass.
b. Meter probe disconnected
or not fully connected to
meter housing.
c. Restricted meter turbine
rotation due to foreign
material in meter !
d. Defective meter probe.
a. Shift bypass valve to not-in-
bypass position.
b. Fully insert probe into meter
housing.
c. Remove meter housing, free
up turbine and flush with
clean water. Turbine should
spin freely. If not, replace
meter. (Contact dealer.)
d. Replace meter cable (Contact
dealer.)
2. Continuous
regeneration.
Camshaft does not
stop at the end of
regeneration.
a. Misaligned optical sensor.
a. Replace optical sensor.
(Contact dealer.)
3. Run out of soft
water between
regenerations.
a. Improper regeneration.
b. Incorrect salt setting.
c. Incorrect hardness or
capacity settings.
d. Water hardness has
increased.
e. Restricted meter turbine
rotation due to foreign
material in meter !
a. Repeat regeneration, making
certain that correct salt
dosage is used.
b. Set salt control to proper level.
See salt setting chart.
c. Set to correct values. See
Programming section.
d. Set hardness to new value.
See Programming section.
e. Remove meter housing, free
up turbine and flush with
clean water. Turbine should
spin freely; if not, replace
meter. (Contact dealer.)