255/440i Troubleshooting

Problem

Possible Cause

Solution

1. Control will not

draw brine.

a. Low water pressure.

b. Restricted drain line.

c. Injector plugged.
d. Injector defective.

e. Air check valve closes

prematurely.

a. Set pump to maintain 20 psi

at softener.

b. Change drain to remove

restriction.

c. Clean injector and screen.
d. Replace injector. (Contact

dealer.)

e. Put control momentarily into

brine/slow rinse. Replace or
repair air check if needed.
(Contact dealer.)

2. System using more

or less salt than
regenerant setting.

a. Foreign matter in

controller causing
incorrect flow rates.

a. Remove brine control and

flush out foreign matter.
Manually position control to
brine/slow rinse to clean
controller (after so doing
position control to "purge” to
remove brine from tank).

3. Intermittent or

irregular brine
draw.

a. Low water pressure.

b. Defective injector.

a. Set pump to maintain 20 psi

at softener.

b. Replace injector. (Contact

dealer.)

4. No conditioned

water after
regeneration.

a. No salt in brine tank.
b. Injector plugged.
c. Air check valve closes

prematurely.

a. Add salt to brine tank.
b. Clean injector and screen.
c. Put control momentarily into

brine/slow rinse. Replace or
repair air check if needed.
(Contact dealer.)

5. Control

backwashes or
purges at
excessively low or
high rate.

a. Incorrect drain controller

used.

b. Foreign matter affecting

controller operation.

a. Replace with correct size

controller. (Contact dealer.)

b. Remove drain controller and

clean ball and seat.