GE Autorol 255 Valve / 400 Series User Manual
Page 14
14
460i Control
Figure 12
Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not
controlled by a switch. Plug the transformer into the transformer plug receptacle on
the control.
Open the access door by pushing the raised tab on the door toward the left while
pulling the tab out (Figure 12).
Time of Day Setting
With the jumper on the set of pins next to the word TIME (Figure 13), set the time of
day to the closest hour by pressing the black TIME SET button. PM hours are indicated
by a light next to the letters PM on the display window.
Note:
The use of a small needle-nose pliers will aid in moving the jumper.
Note:
The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit
regenerate at an earlier or later time, simply set the current time of day accordingly
(e.g., to have the unit regenerate at 4:00 a.m.—two hours later—set the clock two hours
earlier than the actual time of day).
Note:
The Timer Locking Pin should always be horizontal (Figure 12) during
operation.
PM Indicator
Water Flow Indicator
Hour Time Display
Access Door
Indicator Knob
Time Set Button
Transformer Plug
Receptacle
Jumper
Spare
Raised
Tab
Jumper
Locking Pin
Timer