beautypg.com

Iring, Iagram, Roduct – Goodman Mfg GPH15M User Manual

Page 31: Pecifications, Arnin g

background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-GPH15M

www.goodmanmfg.com

31

2

3

SEE NOTE 2

WH

SEE NOTE 3

EM

TR

208-240

3

240

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A

S

T1

R

L1

DF1

C

H

F

RCCF

CM

HVDR

T2

C

DF2

L2

RD

H

RCCF

F

C

YL

BR

PU

2

24V

208

TR

C

BK

1

PU

COMP

CM

BR

BR

PU

4

1

PLF

BK

YL

S

BK

RD

BK

5

6

2

3

C R

LVJB

RD

OR

BL

BR

WH

GR

YL

R

O

C

W2

W1

G

Y2

A

T

O

T

S

M

R

E

H

T

T1

BL

SEE NOTE 3

PU

L1

BL

CSR

C

L2

PU

BK

60

/

/

1

0

4

2

-

8

0

2

7

8

9

BL

0140G02414-A

RD

RD

BK

BK

RD

YL

C L G N

1 2 3

BL

BL

BL

BL

RD

GR

GR

GR

WH

RD

EM

GR

SEE NOTE 2

RVC

LPS

++

1

L

1

3

2

R W2 O W1 Y1

G

C

4
5

6

PLF

EM

1

C

CSR

SEE NOTE 2

SEE NOTE 5

THERMOSTAT

N

G

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

COMPONENT LEGEND

C

CCR

CH

CHS

CM

COMP

CSR

DC

DFT

EM

GND

HPS

HR

HVDR

LPS

LVDR

LVJB

PLF

RVC

RCCF

SA

SOL

TR

CONTACTOR

COMPRESSOR CONTACTOR RELAY

CRANKCASE HEATER

CRANKCASE HEATER SWITCH

CONDENSER MOTOR

COMPRESSOR

COMPRESSOR SOLENOID RELAY

DEFROST CONTROL

DEFROST THERMOSTAT

EVAPORATOR MOTOR

EQUIPMENT GROUND

HIGH PRESSURE SWITCH

HEAT RELAY

HIGH VOLTAGE DEFROST RELAY

LOW PRESSURE SWITCH

LOW VOLTAGE DEFROST RELAY

LOW VOLTAGE JUNCTION BOX

FEMALE PLUG / CONNECTOR

REVERSING VALVE COIL

RUN CAPACITOR FOR

COMPRESSOR AND FAN

START ASSIST

HI STAGE SOLENOID

TRANSFORMER

WIRE CODE

BK BLACK

BL BLUE

BR BROWN

GR GREEN

OR ORANGE

PU PURPLE

RD RED

WH WHITE

YL YELLOW

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTI0NAL HIGH

VOLTAGE

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS

ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW

LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE

ENERGIZED, THE HIGHER SPEED SETTING IS USED.

3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM

TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED

5. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY

EQUIPPED WHEN REQUIRED.

6. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR

COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.

7. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

2

3

SEE NOTE 8

SA

SEE NOTE 4

RD

YL

BK

BK

BK

OR

GR

4 5

HPS

BL

BL

PU

BL/PK

YL/PK

YL

RD

CHS

BK

RD

BK

BK

BK

PU

PU

SEE NOTE 5

SEE NOTE 7

RD

PU

RD

BL

BL

PU

OR

OR

YL

YL

WH

BK

BK

YL

YL/PK

WH

BL

CHS

CH

PU

Y1

SOL

GND

YL

YL

YL

YL

YL

PU

YL

BL

BL

YL

YL

BR

BL

BL

Y2

C

SOL

HPS

T2

7

4

B

A

SEE NOTE 6

YL

BL/PK

PU

CH

GR

BK

SEE NOTE 5

PU

PU

24V

DC

DFT

Y

C

R

RVC

LPS

CNT

R-PS1

PS2

R

W

O

R-DFT

O-RV

C-RV

DFT

2 POLE ONLY

SEE NOTE 6

SEE NOTE 4

PS2

C

C

R

C

Y

Y

R

-PS1

R-

DF

T

DF

T

0

CNT

CCR

HVDR

LVDR

W

C-RV

0-RV

0

DF2

DF

1

R

DC

PU RD

DFT

RD

RD

RD

YL

YL

WH

WH

WH

BL

RD

HR

9

6

YL

YL

YL

HR

2

4

3

1

WH

WH

BL

BL

GR

BL

BL

BL

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

W

arnin

G

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.

w

iring

d

iagram

— gph1549-60m41aC/ad/B*

Applies to GPH1549M41AC (serial #1205184222 & later) & GPH1560M41AC (serial #1205184197 & later)