Auxiliary heating data, Uxiliary, Eating – Goodman Mfg GPH15M User Manual
Page 25: Roduct, Pecifications

P
roduct
S
PecificationS
P
roduct
S
PecificationS
SS-GPH15M
www.goodmanmfg.com
25
a
Uxiliary
h
eating
d
ata
GPH1524M41*
Conditions: 860 CFM; Indoor Air @ 70°F DB
GPH1530M41*
Conditions: 1000 CFM Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP
5K
8K
10K
15K
20K
Capacity
BTU/h
COP
5K
8K
10K
15K
20K
65
29.41
4.14
45.80 56.72 62.18
---
---
65
34.44
4.36
51.51 61.75 68.57 85.64
---
60
27.85
4.00
44.23 55.15 60.61
---
---
60
32.61
4.21
49.67 59.91 66.74 83.80
---
55
26.21
3.84
42.59 53.51 58.97
---
---
55
30.69
4.04
47.75 57.99 64.82 81.88
---
50
24.50
3.66
40.88 51.80 57.26
---
---
50
28.69
3.86
45.75 55.99 62.82 79.88
---
45
22.67
3.46
39.06 49.98 55.44
---
---
45
26.55
3.65
43.62 53.85 60.68 77.75
---
40
21.06
3.28
37.44 48.36 53.82
---
---
40
24.66
3.36
41.73 51.96 58.79 75.86
---
35
19.42
3.09
35.80 46.73 52.19
---
---
35
22.74
3.26
39.81 50.05 56.87 73.94
---
30
15.59
2.52
31.97 42.89 48.35
---
---
30
18.81
2.70
35.88 46.12 52.94 70.01
---
25
14.39
2.38
30.77 41.69 47.15
---
---
25
17.37
2.55
34.43 44.67 51.50 68.56
---
20
13.25
2.24
29.63 40.55 46.01
---
---
20
15.99
2.40
33.06 43.29 50.12 67.19
---
15
12.05
2.09
28.43 39.35 44.81
---
---
15
9.89
2.24
26.95 37.19 44.02 61.08
---
10
10.81
1.92
27.19 38.11 43.57
---
---
10
8.87
2.06
25.94 36.18 43.00 60.07
---
5
9.58
1.74
25.97 36.89 42.35
---
---
5
7.87
1.87
24.93 35.17 42.00 59.06
---
0
8.36
1.56
24.74 35.66 41.12
---
---
0
6.86
1.67
23.93 34.16 40.99 58.06
---
-5
7.13
1.36
23.51 34.43 39.90
---
---
-5
5.85
1.47
22.92 33.16 39.98 57.05
---
-10
5.84
1.15
22.22 33.15 38.61
---
---
-10
7.05
1.23
24.12 34.36 41.18 58.25
---
GPH1536M41*
Conditions: 1200 CFM; Indoor Air @ 70°F DB
GPH1543M41*
Conditions: 1350 CFM; Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP
5K
8K
10K
15K
20K
Capacity
BTU/h
COP
5K
8K
10K
15K
20K
65
44.59
4.02
60.97 71.89 77.35 93.73
---
65
50.28
4.31
67.35 77.58 84.41 101.48
---
60
42.21
3.89
58.59 69.51 74.97 91.36
---
60
47.60
4.16
64.67 74.90 81.73 98.80
---
55
39.73
3.74
56.11 67.03 72.49 88.87
---
55
44.80
4.00
61.87 72.10 78.93 96.00
---
50
37.14
3.57
53.52 64.44 69.90 86.28
---
50
41.88
3.82
58.95 69.18 76.01 93.08
---
45
34.37
3.38
50.75 61.67 67.14 83.52
---
45
38.76
3.61
55.83 66.06 72.89 89.96
---
40
31.92
3.20
48.31 59.23 64.69 81.07
---
40
36.00
3.43
53.07 63.30 70.13 87.20
---
35
29.44
3.02
45.82 56.74 62.20 78.59
---
35
33.20
3.24
50.27 60.50 67.33 84.40
---
30
23.20
2.80
39.58 50.50 55.97 72.35
---
30
24.92
2.53
41.99 52.22 59.05 76.12
---
25
21.41
2.64
37.80 48.72 54.18 70.56
---
25
23.00
2.39
40.07 50.30 57.13 74.20
---
20
19.72
2.49
36.10 47.02 52.48 68.87
---
20
21.18
2.25
38.25 48.48 55.31 72.38
---
15
17.93
2.32
34.31 45.24 50.70 67.08
---
15
19.26
2.10
36.33 46.56 53.39 70.46
---
10
16.09
2.13
32.47 43.39 48.85 65.23
---
10
17.28
1.93
34.35 44.58 51.41 68.48
---
5
14.26
1.94
30.65 41.57 47.03 63.41
---
5
15.32
1.76
32.39 42.62 49.45 66.52
---
0
12.44
1.73
28.82 39.74 45.20 61.59
---
0
13.36
1.58
30.43 40.66 47.49 64.56
---
-5
10.61
1.52
27.00 37.92 43.38 59.76
---
-5
11.40
1.38
28.47 38.70 45.53 62.60
---
-10
8.70
1.28
25.08 36.00 41.46 57.84
---
-10
9.34
1.16
26.41 36.64 43.47 60.54
---
Notes
• COP: Coefficient of performance