Iring, Iagram, Roduct – Goodman Mfg GPH15M User Manual
Page 30: Pecifications, Arnin g

P
roduct
S
PecificationS
P
roduct
S
PecificationS
30 www.goodmanmfg.com
SS-GPH15M
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
⚠
W
arnin
G
High
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.
⚡
2
3
SEE NOTE 2
WH
SEE NOTE 3
EM
TR
208-240
3
240
208-240/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A
S
T1
R
L1
DF1
C
H
F
RCCF
CM
HVDR
T2
C
DF2
L2
RD
H
RCCF
F
C
YL
BR
PU
2
24V
208
TR
C
BK
1
PU
COMP
CM
BR
BR
PU
4
1
PLF
BK
YL
S
BK
RD
BK
5
6
2
3
C R
LVJB
RD
OR
BL
BR
WH
GR
YL
R
O
C
W2
W1
G
Y2
A
T
O
T
S
M
R
E
H
T
T1
BL
SEE NOTE 3
PU
L1
BL
CSR
C
L2
PU
BK
60
/
/
1
0
4
2
-
8
0
2
7
8
9
BL
0140G01644-B
RD
RD
BK
BK
RD
YL
C L G N
1 2 3
BL
BL
BL
BL
RD
GR
GR
GR
WH
RD
EM
GR
SEE NOTE 2
RVC
LPS
1
L
1
3
2
R
W2
O
W1 Y1
G
C
4
5
6
PLF
EM
1
C
CSR
SEE NOTE 2
SEE NOTE 5
THERMOSTAT
N
G
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
COMPONENT LEGEND
C
CCR
CH
CHS
CM
COMP
CSR
DC
DFT
EM
GND
HPS
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF
SA
SOL
TR
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
COMPRESSOR SOLENOID RELAY
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VALVE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
HI STAGE SOLENOID
TRANSFORMER
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTI0NAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
6. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
7. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
8. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
2
3
SEE NOTE 8
SA
SEE NOTE 4
RD
YL
BK
BK
BK
OR
GR
4 5
HPS
BL
BL
BL
PU
BL/PK
YL/PK
YL
RD
CHS
BK
RD
BK
BK
BK
PU
PU
SEE NOTE 5
SEE NOTE 7
RD
PU
RD
BL
BL
PU
BL
OR
OR
YL
YL
YL
WH
BK
BK
YL
YL/PK
WH
BL
BL
CHS
CH
PU
Y1
SOL
GND
YL
YL
YL
YL
YL
PU
YL
BL
BL
YL
YL
YL
BR
BL
BL
BL
Y2
C
SOL
HPS
T2
4
2
1
3
SEE NOTE 6
YL
BL/PK
PU
CH
GR
BK
SEE NOTE 5
BL
BL
24V
DC
DFT
Y
C
R
RVC
LPS
CNT
R-PS1
PS2
R
W
O
R-DFT
O-RV
C-RV
DFT
2 POLE ONLY
SEE NOTE 6
SEE NOTE 4
PS2
C
C
R
C
Y
Y
R
-PS1
R-
DF
T
D
F
T
0
CNT
CCR
HVDR
LVDR
W
C-RV
0-RV
0
D
F
2
D
F
1
R
DC
PU RD
DFT
RD
RD
RD
YL
YL
WH
WH
WH
BL
RD
w
iring
d
iagram
— gph1542, 49-60m41aB/aC/B*
Applies to GPH1549M41AC (serial #1205184221 & prior) & GPH1560M41AC (serial #1205184196 & prior)