beautypg.com

Service – Graco Inc. 241705 User Manual

Page 13

background image

308491

13

Service

04732

29

28

27

18

25

Fig. 20

A

B,16

8. Position the trigger (25) on the gun body. Insert the

pivot pin (28) into the top hole (A) and secure with

the screw (29) on the other side. Place an e-clip

(27) on one end of the trigger pin (18). Slide the

pin through lower trigger holes and through the slot

(B) in the spring guide (16) (turn the spring guide

to align, as needed). Install the other e-clip (27).

See Fig. 20.

Fig. 21

1

21

Turn in until screw

stops

1

03980

9. If it was removed, install the spring tension screw

(21) at the rear of the gun. Then, turn the screw in

until it stops. See Fig. 21.

Test the Gun Before Regular Use

1. Lock the gun trigger safety. Connect a hose to the

gun. Start and prime the pump.

2. Release the gun trigger safety. Trigger the gun into

a waste container. Release the trigger to be sure

the gun immediately stops spraying and that there

are no leaks.

3. If the gun has a diffuser, check the diffuser using

the procedure on page 9.

4. Install the tip guard (30) before regular use.

See Fig. 22.

Fig. 22

03965

30