Magnum H80B and H80P Personal Hubs User Guide (07/95)

GARRETT

19

Using the above information and steps below as a guide,

attach the 10BASE5 drop-cable directly to the DTE connector on the

rear of the H80P.

1. Plug the female end of the cable into the male DTE

connector on the H80P.

2. Engage the AUI connector slide lock (on the cable) to

insure maximum connectivity.

3. Connect the opposite end of the cable into a network

AUI port and engage the port's slide locks.

3.5.3

ThinNet 10BASE2 (BNC) Connections (H80B only)

Connect the ThinNet coax cable to the BNC connector on

the Magnum H80B in the same manner as is done for any standard

BNC connection. The BNC port of the H80B is specially equipped

with an internal termination switch next to the BNC connector. This

eliminates the need to use a "tee" connector when the BNC cable

ends at the connection to the H80B. Some applications may require a

"tee" connector, used as a tap, to allow the 10BASE2 coax segment

to continue on past the H80B unit.

Internal Termination Switch Settings:

Right:

Internal termination -- no "T" connector required.

Left:

External "T" required.