Millenium ro (pump pressure adjustment procedure) – GE OSMONICS MILLENIUMTM REVERSE OSMOSIS UNIT User Manual
Page 95
M
Millenium™ RO System by GE Osmonics
14693e - 31 Mar 03
6 - 14
Drawings
6. TURN ON WATER AND POWER AND THEN CHECK PRESSURE READING. REPEAT AS NECESSARY.
4. USE SCREWDRIVER AND TURN SCREW AS SHOWN. CLOCKWISE TO INCREASE PRESSURE, COUNTER
CLOCKWISE TO DECREASE PRESSURE. EACH 90° ROTATION WILL CHANGE PRESSURE ABOUT 25 PSI.
WASHER
PUMP
ACORN NUT
INCREASE
PRESSURE ADJ. SCREW
DECREASE
PROCEDURE:
TOOLS REQUIRED:
5. REPLACE WASHER (IF IT CAME OFF) AND ACORN NUT.
2. OPEN FRONT COVER AND EXPOSE PUMPHEAD.
3. REMOVE ACORN NUT. NOTE: DO NOT LOSE WASHER.
1. TURN OFF POWER AND WATER TO UNIT.
1. FLAT BLADE SCREWDRIVER.
2. 3/4" WRENCH OR EQUIVALENT.
3. TOWEL.
Millenium RO
(Pump Pressure Adjustment Procedure)
See also other documents in the category GE Water equipment:
- Autotrol Performa ProSoft 960 Series (32 pages)
- SmartWater PNRQ15 (6 pages)
- SmartWater GXWH20F (16 pages)
- SmartWater GXSV10C (48 pages)
- Merlin (28 pages)
- PNRQ20FBB (84 pages)
- E4 (33 pages)
- GNSV25CBL (16 pages)
- GXSF27E (60 pages)
- GX1S01C (2 pages)
- ZDWC240 (16 pages)
- GXRM10RBL (64 pages)
- 400 Series (28 pages)
- SmartWater GXWH35F (2 pages)
- PNSF31Z01 (28 pages)
- F-801 (124 pages)
- GN1S04C (36 pages)
- 000 gpd (45 pages)
- GXCF20FBB (28 pages)
- 3020511 (4 pages)
- GXRM10G (64 pages)
- r10279v (8 pages)
- Z-10000 (128 pages)
- GNSV70F (2 pages)
- 268 (44 pages)
- WineChiller (32 pages)
- PNRQ21LRB (84 pages)
- GXPL03H (12 pages)
- GXSV65F (20 pages)
- MONACO 6000A (28 pages)
- GXFM03C (6 pages)
- GXSF35E (64 pages)
- GXRTDR (4 pages)
- Monogram ZDWI240WII (3 pages)
- GXSF30H (2 pages)
- GXFM07HWW (20 pages)
- GXSF4OH (64 pages)
- Profile Wine Chiller (32 pages)
- GXCF05D (24 pages)
- GXCF25FBS (28 pages)
- GNSV75F (2 pages)
- GNSH45E (64 pages)
- GXRM10GBL (2 pages)
- SmartWater GXRLQR (6 pages)
- GNULQ (16 pages)