General Information
1.10.4 Dimensions
Vertical Cabinet Horizontal
Cabinet
Height
25
½
inches
8
inches
Depth
15
inches
15
inches
Width
8
inches 25½
inches
Weight – Operating – 55 lbs.
1.10.5 Membrane Performance Characteristics
Salt rejection (TF Membranes):
95% minimum at initial testing at factory.
Test Solution:
Inlet water 1000 PPM NaCl
Conductivity:
2000
micro
mhos-cm
Operating Pressure:
190 PSI, ±10 PSI
Product Back pressure:
0 PSI
1.10.6 Environmental
Requirement
Minimum
Maximum
Ambient
Temperature
4°C
(39°F)
32°C
(90°F)
Storage
Temperature
2°C
(36°F)
32°C
(90°F)
Altitude
N/A
10,000
feet
CAUTION:
This equipment must not be allowed to freeze. Irreparable harm to various
components, including RO membranes may result.
NOTE:
The user/operator should recognize that moisture can be caused by condensation
and is not necessarily an equipment leak. This equipment will function in the
presence of condensation.
1.11
Disposal
Disposal of this product or parts must be carried out according with local disposal codes.