connects to the PSX-T chassis. Ensure that each lead is securely tightened, then replace safety
shield. When power is applied, the green PWR LED will illuminate


NOTE (1):

Always use a voltmeter to measure the voltage of the incoming power supply

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will
connect to the post labeled “+ve” and the rest to the “-ve”.
The GND can be hooked up at the last.
NOTE (2
):

For best results at high-temperature, fasten the metal case of the PSX unit

to be in contact with a vertical surface (such as pedestal) that has good heat conducting
properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the
best heat transfer away from the PSX unit.

UL Requirements

The following must be adhered to in order to conform to UL requirements:

6. Minimum 18 AWG cable for connection to a Centralized DC power source.
7. Minimum 14 AWG cable for connection to earthing wiring.
8. Use only with Listed 10 A circuit breaker provided in building installation.
9.
“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or

equivalent.

10. Fastening torque of the lugs on the terminal block: 9 inch pound max.
Centralized DC Power Source cable securement, use at least four cable ties to secure the
cable to the rack at least 4 inches apart with the first one located within 6 inches of the
terminal block.


3.4

Cable Strain Relief Feature on all P62-Series models

The Magnum P62-Series Hardened Switches are designed to use in extended

temperature environments, which qualifying them to be used in roadside traffic data collection

and control stations, above-the-ceiling locations in commercial buildings, etc. They are usually

mounted vertically so that the cables hang out the bottom. There is a cable strain relief feature

provided as part of the package

design

The Magnum P62-

Series Hardened Switches have

a tie wrap holder as part of the

base plate of the unit for cable

strain relief. The strain-relief

feature is applicable to power

cables as well as to Ethernet

cables, both twisted-pair copper

and fiber. Cable tie-wraps can

secure the cables and can be