Problem

Possible Causes

What To Do

No Water

Water supply valve

Turn water supply valve on. See diagram on page 11.

not turned on.

After filter change,

It takes 3–4 hours for RO system to provide enough

tank is empty.

water to fill the tank.

Leaks at fittings

Improperly installed.

Reinstall. See Installation Instructions.

Sounds you may hear

Sink drain, drain water

This is normal.

from system.

Drain line can be installed to an alternative drain,

such as a basement drain. See pages 15 and 16
for alternative drain configurations.

Faucet air gap—drain water

Install a pressure regulator in the house water supply

flowing through the faucet

system to reduce the pressure below 90 psi.

air gap. This may be associated

An alternative flow restrictor for high pressure

with high pressure water supply,

installations is available from GE (see item #31 on the

generally 90 psi or greater.

parts list, page 25). Contact GE Parts and ask for Flow
Restrictor, High Pressure, Part Number WS15X10049.

Common problems associated with filter
or RO cartridge replacement.