Problem
Possible Causes
What To Do
No Water
Water supply valve
• Turn water supply valve on. See diagram on page 11.
not turned on.
After filter change,
• It takes 3–4 hours for RO system to provide enough
tank is empty.
water to fill the tank.
Leaks at fittings
Improperly installed.
• Reinstall. See Installation Instructions.
Sounds you may hear
Sink drain, drain water
• This is normal.
from system.
• Drain line can be installed to an alternative drain,
such as a basement drain. See pages 15 and 16
for alternative drain configurations.
Faucet air gap—drain water
• Install a pressure regulator in the house water supply
flowing through the faucet
system to reduce the pressure below 90 psi.
air gap. This may be associated
• An alternative flow restrictor for high pressure
with high pressure water supply,
installations is available from GE (see item #31 on the
generally 90 psi or greater.
parts list, page 25). Contact GE Parts and ask for Flow
Restrictor, High Pressure, Part Number WS15X10049.
Common problems associated with filter