beautypg.com

Before you call for service – GE PNRQ21LBN User Manual

Page 22

background image

Operating Instructions

Safety Instructions

Installation Instructions

Tr

oubleshooting T

ips

Consumer Support

Troubleshooting Tips

22

Problem

Possible Causes

What To Do

Chlorine taste and/or

The ppm of chlorine in your

If the water supply contains more than 2.0 ppm of chlorine,

odor in the Reverse

water supply exceeds maximum

additional filtering of the water supply to the Reverse

Osmosis product water

limits and has destroyed the

Osmosis is needed. Correct this condition before doing

Reverse Osmosis membrane.

maintenance on the Reverse Osmosis system.

The prefilter is no longer

Replace the Reverse Osmosis membrane cartridge,

removing chlorine from

flow control, screen, prefilter, postfilter and battery

the water supply.

in the faucet base.

Other taste and/or odor

High quality product water

This is normal.

may have a different taste
than what you’re used to.

Low water usage.

Completely drain system and allow to refill.

Contamination in product

Use sanitizing procedures.

water storage.

Prefilter and postfilter

Replace the prefilter and postfilter.

need to be changed.

Sanitize system.

Water leaking from

Drain side of faucet air gap

Inspect and eliminate restriction or plug. It is important

faucet air gap hole

(3/8

tubing) plugged,

that there are no dips, loops or low spots in the drain line

restricted or incorrectly

from the faucet air gap to the drain pipe. Refer to

connected to the drain.

Installation Instructions for proper drain connection.
If drain line adapter was used as the drain point,
periodic inspection/cleaning is recommended.

System makes product

This is normal.

Water flow rate will be lower than your regular faucet.

water slowly

It takes 3–4 hours to fill the tank.

Water supply to the Reverse

Increase water pressure, precondition the water, etc.,

Osmosis system not within

as needed to conform before doing maintenance on

specifications.

the Reverse Osmosis system.

Prefilter cartridge plugged

Replace the prefilter. If rate does not increase, replace

with sediments.

the postfilter.

Reverse Osmosis membrane

Replace Reverse Osmosis membrane cartridge, flow

plugged with sediments.

control and battery in the faucet base.

Before you call for service…

This manual is related to the following products: