GE Z-14400 User Manual
Page 21
Z Series RO System by GE Osmonics
1.11.2 Flow
Rates
1.
Product flow rates based on the following conditions with product flow equal to
waste flow:
Operating Pressure:
200 - 250 PSI
Product
Pressure:
1
PSI
pH:
6.5
Feed
Water
Temperature:
77
°F (25°C)
Product Flow Rate
Model
Number
GPM LPM GPD LPD
Indirect Units
Z-9600 6.67
25.24
9,600
36,340
Z-12000 8.33
31.55
12,000
45,425
Z-14400 10
37.85
14,400
54,510
Direct Units
Z-6000 4.17
15.77
6,000
22,712
Z-8000 5.56
21.03
8,000
30,283
Z-10000 6.94
26.29
10,000
37,854
Z-12000 8.33
31.55
12,000
45,425
1.11.3 Electrical
Requirements
1. RO
Units
Voltage Hertz Amps Phase Hp
230 60 24 1 5
208 60
20/27.5 3 5/7.5
230 60 16/24 3 5/7.5
460 60
8.5/12.5
3 5/7.5
2.
Product Divert Controller
Receptacle
Type
Standard
Voltage 115
/
230~
Hertz
60
/
50
Amps
20
Phase
Single
1238339b – 16Oct03
1 - 15