beautypg.com

Friedrich ZQ08A10C User Manual

Page 8

background image

—8—

2.3.4 POWER CORD

1. Remove the control box. (Refer to section 2.1.3)
2. Open the control box. (Refer to section 2.3.3)
3. Disconnect the grounding screw from the control

box.

4. Disconnect the 2 receptacles.
5. Remove a screw which fastens the clip cord.

(See Figure 10)

6. Remove the power cord.
7. Re-install the component by referring to the above

removal procedure, above.
(Use only one ground-marked hole for ground
connection.)

8. If the supply cord of this appliance is damaged, it

must be replaced by the special cord. (The
special cord means the cord which has the same
specification marked on the supply cord attached
at the unit.)

2.3.5 THERMOSTAT

1. Remove the control box. (Refer to section 2.1.3)
2. Open the control box. (Refer to section 2.3.3)
3. Remove the 2 screws which fasten the thermostat.
4. Disconnect 2 leads of thermostat terminals.
5. Remove the thermostat.
6. Re-install the components by refereing to the

above removal procedure. (See Figure 11)

2.3.6 ROTARY SWITCH

1. Remove the control box. (Refer to section 2.1.3)
2. Open the control box. (Refer to section 2.3.3)
3. Remove the 2 screws which fasten the rotary

switch.

4. Disconnect all the leads of the rotary switch

terminals.

5. Remove the rotary switch.
6. Re-install the components by referring to the

above removal procedure. (See Figure 12)

2.3.7 MOTOR

1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the evaporator. (Refer to section 2.2.1)
3. Remove the orifice. (Refer to section 2.2.1)
4. Remove the blower. (Refer to section 2.2.1)
5. Remove the fan. (Refer to section 2.2.2)
6. Remove the control box cover and housing of the

motor in the control box. (Refer to section 2.1.3)

7. Remove the 2 screws which fasten the motor from

the mount motor. (See Figure 13)

8. Remove the motor.
9. Re-install the components by referring to the

removal procedure, above.(See Figure 13)

Figure 10

Figure 11

Figure 12