Fujitsu Siemens Computers Mini Speaker Set USB User Manual
Page 318

PRIMEPOWER Options
Data Sheets: http://www.fujitsu-siemens.com/primepower
Category
Description
Details
P
R
IME
P
O
W
E
R 1500
PRI
M
EPO
WER 2
5
0
P
R
IME
P
O
W
E
R 2500
P
R
IME
P
O
W
E
R 250F
P
R
IME
P
O
W
E
R 250N
PRI
M
EPO
WER 4
5
0
P
R
IME
P
O
W
E
R 450N
PRI
M
EPO
WER 6
5
0
PRI
M
EPO
WER 8
5
0
PRI
M
EPO
WER 9
0
0
PRI
M
EPO
WER p
ro
je
c
ts
PW RACK Co
n
s
o
le
S
ystem
Console
C
ode
E
nd User
P
rice (£)
C
o
mme
n
ts
Options matrix
Communication/Network (Continued)
Quad Fast/Gigabit Ethernet Contr., RJ45
This Quad Fast/Gigabit Ethernet Controller with for connectors allows the connection
to an Ethernet network via copper cable (cat 5e) to a CSMA/CD network in
accordance with IEEE 802.3ab with the physical variant 10/100/1000BASE-T. The
controller automatically senses the network speed and the operating mode (half-
duplex or full-duplex). Each port has its own MAC address. VLAN tagging according
IEEE 802.1q and link aggregation according IEEE 802.3ad (except LACP) are
supported. Also DR (dynamic reconfiguration) and PHP (PCI hot plug) in
corresponding systems. Speed 33/66 MHz, 64 bit bus width. This Controller is RoHS
compliant according to the EU Directive 2002/95/EC.
x
x
x
x
x
x
x
x
x D:GP70F-CL21
909
Quad Fast/Gigabit Ethernet Contr., RJ45
This Quad Fast/Gigabit Ethernet Controller with for connectors allows the connection
to an Ethernet network via copper cable (cat 5e) to a CSMA/CD network in
accordance with IEEE 802.3ab with the physical variant 10/100/1000BASE-T. The
controller automatically senses the network speed and the operating mode (half-
duplex or full-duplex). Each port has its own MAC address. VLAN tagging according
IEEE 802.1q and link aggregation according IEEE 802.3ad (except LACP) are
supported. Also DR (dynamic reconfiguration) and PHP (PCI hot plug) in
corresponding systems. Speed 33/66 MHz, 64 bit bus width. This Controller is RoHS
compliant according to the EU Directive 2002/95/EC.
x
x
x
x
x
x
D:GP70F-CL21
909
WAN Controller PWXV (X.21, V.24, V.35)
x
x
x
x
x
x
D:GP71F-CW50
2073
WAN Controller PWXV (X.21, V.24, V.35)
x
x
x
x
x
x
x
x
D:GP71F-CW50
2073
WAN Submodul
x
x
x
x
x
x
D:GP71F-CW51
965
WAN Submodul
x
x
x
x
x
x
x
x
D:GP71F-CW51
965
Adaptercable for PCI Contr. V.24
x
x
x
x
x
x
D:KB236-C150
90
Adaptercable for PCI Contr. V.24
x
x
x
x
x
x
x
x
D:KB236-C150
90
Adaptercable for PCI Contr. V.35
x
x
x
x
x
x
D:KB237-C150
153
Adaptercable for PCI Contr. V.35
x
x
x
x
x
x
x
x
D:KB237-C150
153
Adaptercable for PCI Contr. X.21
x
x
x
x
x
x
D:KB238-C150
90
Adaptercable for PCI Contr. X.21
x
x
x
x
x
x
x
x
D:KB238-C150
90
ISDN Controller PWS0 (2x S0)
x
x
x
x
x
x
D:GP71F-CW56
1815
ISDN Controller PWS0 (2x S0)
x
x
x
x
x
x
x
x
D:GP71F-CW56
1815
ISDN Controller PWS2 (1x S2M)
x
x
x
x
x
x
D:GP71F-CW57
5721
ISDN Controller PWS2 (1x S2M)
x
x
x
x
x
x
x
x
D:GP71F-CW57
5721
Serieller I/O Controller
This CONTROLLER orders over 8 asynchronous ports RS232, with D-sub plug 25
pin. The transmission takes place full-duplex. The CONTROLLER can be operated in
the 7-bit and 8-bit mode. Those max. Transmission rate amounts to 60-115.2 kbit/s.,
This controller is Solaris 10 ready !
x
x
x
x
x
x
x
x
x D:GP70F-CT12
874
Serieller I/O Controller
This CONTROLLER orders over 8 asynchronous ports RS232, with D-sub plug 25
pin. The transmission takes place full-duplex. The CONTROLLER can be operated in
the 7-bit and 8-bit mode. Those max. Transmission rate amounts to 60-115.2 kbit/s.,
This controller is Solaris 10 ready !
x
x
x
x
x
x
D:GP70F-CT12
874
Rack-Infrastructure
Console connection unit PRIMEPOWER-XA
Takes 1 unit in a 19 inch rack, 8 serial ports (D-sub, 9pin), 1 Ethernet port 10Base T
(IEEE802.3, RJ45).
x
x
x
D:GP70X-RC11
3497
PW_Baseplate f. Teleservice Modems, 1HU
This baseplate is used for 2 teleservice modems, maximum bearing force, static =
50kg., , For mounting into a PCR1-rack (GP70F-BG4x) you have to order one support
bracket 1HU (GP70F-ZB211) in addition.
x
x
D:GPRAC-GB523
140
2-joint arm for cable guidance, towed
The 2-joint arm for cable guidance take the cable for 19inch server build-in into
foreign/3rd-party-racks. Server height > 2HU and with telescopic rails. So you don´t
need to unlock the cables, when you pull out the systems for services.
x
x
x
D:GPRAC-ZB523
112
Cable magmt. for 19" DC- PC- Rack
Cablemanagement for adding a server or storage subsystem into the PRIMECENTER
rack 2
x S26361-F2735-E7
27
E_PDU IEC320-10A > 3xSchuko
E_PDU = Power distribution unit, expansion, 3-way socket strip with 3 grounded
(Schuko, each 16A) plug sockets and 1 IEC320 connector plug 10A!, For connection
to SV011, SV13, SV33., To connect the mains adapter from teleservice modem.
x
x
D:GPRAC-SV03
59
Ethernet Switch 8 Port 10/100 Mbps
Ethernet Switch 8Port 10 / 100Mbps with a 2 area power supply for 110 V / 230 V. For
desktop variant a power cord with Schuko connector is provided., Caskading of Eth.
Switch to Eth. Switch is possible for cable: GP7KB-13xx.
x
x
D:GP70F-AL21
140
Consoleswitch 8port+1analog-Con(0801)1U
Consoleswitch 8port with On-Screen-Display function (OSD) for switching of
keyboard/monitor/mouse up to 8 systems to 1analog-console, For desktop installation
a cable with cold device socket IEC320 and a country-specific plug is in addition to
order., If the new firmware isn´t available on the delivered CD, you can download the
firmware!
x
x
D:GPRAC-KS0801
1084
Rack mounting kit for PRIMESTATION
19inch rack mounting kit for PRIMESTATION TS21/T25
x
x
D:GPRAC-ZB26
152
1x Runner set for 19" Tray
This sliding rail set is used for 19inch components llike BG55 or PRIMESTATION into
a rack. This sliding rail set must be ordered separately.
x
x
D:GP70F-ZB20
38
Support bracket 1U for 19inch units PCR1
The assembly kit contains one mounting bracket only for BG4x (PCR1) for installing
19" modules on the rear, right-hand cross-member (630mm to 19inch)., see Rack-
configurator
x
D:GP70F-ZB211
38
Support bracket 1U for 19inch units PCR1
The assembly kit contains one mounting bracket only for BG4x (PCR1) for installing
19" modules on the rear, right-hand cross-member (630mm to 19inch)., see Rack-
configurator
x
x
D:GP70F-ZB211
38
Support bracket 1U for 19inch units PCR2
The assembly kit contains one 1HUsupport bracket for installing 19" modules on the
rear, right-hand cross-member (630mm to 19inch).
x
x
x
x
x
D:GPRAC-ZB5211
42
Support bracket 1U for 19inch units PCR2
The assembly kit contains one 1HUsupport bracket for installing 19" modules on the
rear, right-hand cross-member (630mm to 19inch).
x
x
x
x
x
D:GPRAC-ZB5211
42
Support bracket 2U for 19inch units PCR2
The assembly kit contains one 2U mounting bracket for installing 19" modules on the
rear, right-hand cross-member (630mm to 19inch)., Upload up to 150kg
x
x
x
x
D:GPRAC-ZB5212
45
Tragewinkel 3HE für 19"-Einbauten PCR2
The assembly kit contains one 3HU mounting bracket for installing 19" modules on the
rear, right-hand cross-member (630mm to 19inch)., Upload up to 150kg
x
x
D:GPRAC-ZB5215
63
Rear mounting kit for hubs/switches
The assembly kit contains one 1U support bracket and 1 dummy panel 1U for the
front.
x
x
D:GPRAC-ZB5214
63
cable carrier BG5x, laterally assembly
The cable guide take the cable for 19inch build-in > 1U and with telescop trays. So
you don´t need to unlock the cables, when you pull out the systems for services. Look
about the order quantity in the configurator.
x
x
x
x
x
x
x D:GPRAC-ZB527
45
cable carrier BG5x, laterally assembly
The cable guide take the cable for 19inch build-in > 1U and with telescop trays. So
you don´t need to unlock the cables, when you pull out the systems for services. Look
about the order quantity in the configurator.
x
x
x
D:GPRAC-ZB527
45
Cable carrier for I/O cabinet PW1500
MOUNTING KIT WITH CABLE CARRIER I/OCAB
x
x
x D:GP70X-ZB22
98
Mounting kit I with cable carrier PCR2
One cable carrier ZB527 with one 2U support bracket ZB5212
x D:GPRAC-ZB560
84
Mounting kit II with cable carrier PCR2
Two cabel carriers with one 3U support bracket.
x
x
D:GPRAC-ZB561
147
Fujitsu Siemens Computers
Price book November 7th 2007