beautypg.com

3 checking and updating firmware / bootbios, Checking and updating firmware /bootbios, 3 checking and updating firmware /bootbios – FUJITSU PRIMERGY 4Gbit/s FC I/O Modules User Manual

Page 20: Pg.58), Checking and updating firmware / bootbios, 1 using lightpulse utility / nt

background image

58

4.3

Checking and Updating Firmware /
BootBIOS

There are two methods to check and update Firmware/BootBIOS. The results will bring no

difference.

"4.3.1 Using LightPulse Utility / NT"(pg.58)

"4.3.2 Using HBAnyware Utility"(pg.60)

4.3.1

Using LightPulse Utility / NT

This product name displayed in LightPulse Utility/NT is "Adapter * - BX600-FC42E * Port *".

1

Click the "Start" button

"Programs" or "All Programs"

"Emulex"

"lpUtilNT" in this order.

2

Select "Firmware Maintenance" in the "Category" field.

For PG-FCD201, Adapter 0 and 1 are displayed.

3

For the firmware version, check the "Revision" value in "Functional
Firmware".

• When the version is "2.70x6", proceed to Step 7.

• When the version is other than "2.70x6", proceed to Step 4.

4

Click [Download].

Although the warning window appears, click [OK].

5

Insert the driver disk (CD-ROM) into the CD-ROM drive, select the
Firmware file in the CD-ROM drive, and click [Open].

[CD-ROM drive]:\FirmBIOS\zf2.70x6.all

Firmware update starts.

6

Check the "Revision" value in "Functional Firmware" is "2.70x6".