5 timer minimum measurement unit, Timer minimum measurement unit – FUJITSU SOFTUNE F2 MC-16 User Manual
Page 87
73
CHAPTER 2 DEPENDENCE FUNCTIONS
2.2.1.5
Timer Minimum Measurement Unit
The timer minimum measurement unit affects the sequencer, the emulation timer and the
performance measurement timer.
■
Setting Timer Minimum Measurement Unit
Choose either 1
μs or 100 ns as the timer minimum measurement unit for the emulator for measuring time.
The minimum measurement unit for the following timers is changed depending on this setup.
•
Timer values of sequencer (timer conditions at each level)
•
Emulation timer
•
Performance measurement timer
Table 2.2-3 shows the maximum measurement time length of each timer when 1
μs or 100 ns is selected as
the minimum measurement unit.
When the minimum measurement unit is changed, the measurement values of each timer are cleared as well.
The default setting is 1
μs.
Use the following commands to control timers.
SET TIMERSCALE :
Sets minimum measurement unit for timers
SHOW TIMERSCALE :
Displays status of minimum measurement unit setting for timers
[Example]
>SET TIMERSCALE/100N
>SHOW TIMERSCALE
Timer scale : 100ns
>
Table 2.2-3 Maximum Measurement Time Length of Each Timer
1
μ
s selected
100 ns selected
Sequencer timer
About 16 seconds
About 1.6 seconds
Emulation timer
About 70 minutes
About 7 minutes
Performance measurement timer
About 70 minutes
About 7 minutes