FUJITSU SOFTUNE F2 MC-16 User Manual
Page 138
124
CHAPTER 2 DEPENDENCE FUNCTIONS
■
Setting Events
Set events using the SET EVENT command.
The starting/ending point of time measurement and points to measure pass count are specified by events.
Events at 8 points (1 to 8) can be set. However, in the performance measurement, the intervals, starting event
number and ending event number are fixed in the following combination.
- Measuring Time
Four intervals have the following fixed event number combination.
- Measuring Count
The specified events become performance measurement points automatically.
■
Executing Program
Start measuring when executing a program by using the GO or CALL command. If a break occurs during
interval time measurement, the data for this specific interval is discarded.
■
Displaying Performance Measurement Data
Display performance measurement data by using the SHOW PERFORMANCE command.
■
Clearing Performance Measurement Data
Clear performance measurement data by using the CLEAR PERFORMANCE command.
[Example]
>CLEAR PERFORMANCE
>
Interval
Starting Event Number
Ending Event Number
1 1
2
2 3
4
3 5
6
4 7
8