2 display performance measurement data, Display performance measurement data – FUJITSU SOFTUNE F2 MC-16 User Manual
Page 201
187
CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.7.2
Display Performance Measurement Data
Display the measured time and measuring count by using the SHOW PERFORMANCE
command.
■
Displaying Measured Time
To display the time measured, specify the starting event number or the ending event number.
>SHOW PERFORMANCE/TIME 1,9000,18999,1000
event
= 1 -> 2
time (
µ
s)
| count
min time
= 11637.0
-----------------------------+---------
max time
= 17745.0
0.0 -
8999.0
|
0
avr time
= 14538.0
9000.0 -
9999.0
|
0
10000.0 -
10999.0
|
0
11000.0 -
11999.0
|
2
12000.0 -
12999.0
|
19
13000.0 -
13999.0
|
52
14000.0 -
14999.0
|
283
15000.0 -
15999.0
|
92
16000.0 -
16999.0
|
3
17000.0 -
17999.0
|
1
18000.0 -
18999.0
|
0
19000.0 -
|
0
-----------------------------+---------
tot
al
|
452
Minimum
execution time
Event number
Maximum
execution time
Average
execution time
Count of measuring within given time interval
Total measuring count
>SHOW PERFORMANCE/TIME 1,13000,16999,500
event = 1 -> 2
time (
µ
s)
| count
min time = 11637.0
-----------------------------+---------
max time = 17745.0
0.0 -
12999.0
|
21
avr time = 14538.0
13000.0 -
13499.0
|
13
13500.0 -
13999.0
|
39
14000.0 -
14499.0
|
121
14500.0 -
14999.0
|
162
15000.0 -
15499.0
|
76
15500.0 -
15999.0
|
16
16000.0 -
16499.0
|
2
16500.0 -
16999.0
|
1
17000.0 -
17499.0
|
1
-----------------------------+---------
total
|
452
Upper time limit for display
Lower time limit for display