beautypg.com

FUJITSU SPARC M9000 User Manual

Page 3

background image

Installation Steps for SPARC Enterprise M8000/M9000 Servers

Step 1

• Check the power source, air conditioning equipment, and location of the installation site.

For details, see the SPARC Enterprise M8000/M9000 Servers Site Planning Guide.

Step 2

• Unpack the product package by referencing the SPARC Enterprise M8000/M9000 Servers

Unpacking Guide, which comes with the server.

Step 3

• Install the main unit. If there is an expansion cabinet to be connected to the SPARC Enterprise

M9000 or a power supply cabinet to be mounted in the SPARC Enterprise M8000 or SPARC
Enterprise M9000, connect each of them to the relevant cabinet. For details, see the SPARC
Enterprise M8000/M9000 Servers Installation Guide
.

Step 4

• Connect the input power cables to the main unit. For details, see the SPARC Enterprise

M8000/M9000 Servers Installation Guide.

Step 5

• Connect the console to the main unit. For details, see the SPARC Enterprise M8000/M9000

Servers Installation Guide.

Step 6

• Turn on the main line switch of the main unit. For details, see the SPARC Enterprise M8000/

M9000 Servers Installation Guide.

Step 7

• Set necessary information for hardware. For details, see the SPARC Enterprise M8000/M9000

Servers Installation Guide.

Step 8

• Turn on the power to the main unit. POST is automatically executed after power-on. For

details, see the SPARC Enterprise M8000/M9000 Servers Installation Guide.

Step 9

• Set a LAN port on the XSCF unit and connect it. For details, see the SPARC Enterprise

M8000/M9000 Servers Installation Guide and the SPARC Enterprise M4000/M5000/M8000/
M9000 Servers XSCF User’s Guide
.

Step 10

• If you are installing other peripheral devices in the main unit, proceed to Step 11.
• If you are not installing peripheral devices in the main unit, proceed to Step 14.

Step 11

• Turn off the power to the main unit. For details, see the SPARC Enterprise M8000/M9000

Servers Installation Guide.

Step 12

• Install other peripheral devices. For details, see manuals supplied with each peripheral

device.

Step 13

• Turn on the power to the main unit. POST is automatically executed after power-on. For

details, see the SPARC Enterprise M8000/M9000 Servers Installation Guide.

Step 14

• Check the network connection of domain. For details, see the SPARC Enterprise M8000/

M9000 Servers Installation Guide.

Step 15

• Confirm the operation by using SunVTS. For details, see the SPARC Enterprise M8000/

M9000 Servers Installation Guide and the SunVTS User's Guide

.

Step 16

• Perform the setup required for the operation of the system. For details, see the SPARC

Enterprise M4000/M5000/M8000/M9000 Servers Administration Guide.
Notes:
We recommend you to install Enhanced System Facility (ESF) and apply PTF for safe
operation of the system. See the following

website

for details.

http://www.fujitsu.com/sparcenterprise/manual

This manual is related to the following products: