FS-100 Functions

FS-100 Portable DTE Recorder

53

EXT CTL FILE

Creates a new file during a record session without losing
frames.

TIME CODE EXT, REC RUN, FREE RUN, REGEN

The following are timecode (

TC

) functions.

TC EXT

Group Default

Records the incoming source timecode. If the timecode is not
running, the FS-100 records the same timecode number in
each recorded frame. Choose

TC EXT

mode to clear any

stored number.

TC REC RUN
In this mode, after a power cycle, the FS-100 starts its TC record
count using the

TC SET

value. Later recordings add to the last value

recorded. A power cycle resets the TC record value to the

TC SET

value.

TC FREE RUN

This function causes the FS-100 to begin counting from the
value stored by

TC SET

.

A number entered through

TC SET

is not stored and available

to the FS-100 until exiting

TC SET

. Only then does the FS-100

begin counting using that number.

TC REGEN

When the FS-100 powers up in

TC REGEN

mode, it:

Reads the timecode of the last track recorded.

Adds 1 to the number.

Stores the new timecode as the number that will be assigned to
the first frame of the next recording session.

If the drive is empty, i.e. no existing recordings with, the
FS-100 uses the

TC SET

value.

TC SET and UB SET Can Be Set at the Same Time

Both parameters, TC SET and UB SET, may be set and are not mutually
exclusive as in some groups, i.e. LCDLIGHT.

TC EXT Recommended for Pull-down Applications

If the recording signal contains pull-down information in 720/60p format, the
frame flag information contained is preserved in TC EXT mode and is
required for the editing process.