AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers
F i n i s a r
9/26/02 Revision D
Page 7
Transceiver
1
The following bit significant indicators define the electronic
or optical interfaces that are
2
supported by the transceiver. At least one bit shall be set in this field. For Fibre Channel
3
transceivers, the Fibre Channel speed, transmission media, transmitter technology, and
4
distance capability shall all be indicated. The SONET Compliance Codes are described
5
in more detail in table 3.4a.
6
Table 3.4: Transceiver codes
7
8
Data
Addr
Bit
1
Description of transceiver
Data
Addr
Bit
1
Description of transceiver
Reserved Standard Compliance Codes
Fibre Channel link length
3
7-0
Reserved
7
7
very long distance (V)
4
7-5
Reserved
7
6
short distance (S)
SONET Compliance Codes
7
5
intermediate distance (I)
4
4
SONET reach specifier bit 1
7
4
long distance (L)
4
3
SONET reach specifier bit 2
Fibre Channel transmitter technology
4
2
OC 48, long reach
7
3-2
Reserved
4
1
OC 48, intermediate reach
7
1
Longwave laser (LC)
4
0
OC 48 short reach
7
0
Electrical inter-enclosure (EL)
5
7
Reserved
8
7
Electrical intra-enclosure (EL)
5
6
OC 12, single mode long reach
8
6
Shortwave laser w/o OFC (SN)
5
5
OC 12, single mode inter. reach
8
5
Shortwave laser w/ OFC (SL)
5
4
OC 12 multi-mode short reach
8
4
Longwave laser (LL)
5
3
Reserved
8
0-3
Reserved
5
2
OC 3, single mode long reach
5
1
OC 3, single mode inter. reach
Fibre Channel transmission media
5
0
OC 3, multi-mode short reach
9
7
Twin Axial Pair (TW)
9
6
Shielded Twisted Pair (TP)
9
5
Miniature Coax (MI)
Gigabit Ethernet Compliance Codes
9
4
Video Coax (TV)
6
7-4
Reserved
9
3
Multi-mode, 62.5m (M6)
6
3
1000BASE-T
9
2
Multi-mode, 50 m (M5)
6
2
1000BASE-CX
9
1
Reserved
6
1
1000BASE-LX
9
0
Single Mode (SM)
6
0
1000BASE-S X
Fibre Channel speed
10
7-5
Reserved
10
4
400 MBytes/Sec
10
3
Reserved
10
2
200 MBytes./Sec
10
1
Reserved
10
0
100 MBytes/Sec
1