Calibration Constants

1

2

TABLE 3.15: Calibration constants for External Calibration Option

3

(2 Wire Address A2h)

4

5

Address

# Bytes

Name

Description

56-59

4

Rx_PWR(4)

Single precision floating point calibration data - Rx optical power. Bit
7 of byte 56 is MSB. Bit 0 of byte 59 is LSB. Rx_PWR(4) is set to
zero for “internally calibrated” devices.

60-63

4

Rx_PWR(3)

Single precision floating point calibration data - Rx optical power.
Bit 7 of byte 60 is MSB. Bit 0 of byte 63 is LSB. Rx_PWR(3) is set to
zero for “internally calibrated” devices.

64-67

4

Rx_PWR(2)

Single precision floating point calibration data, Rx optical power.

Bit 7 of byte 64 is MSB, bit 0 of byte 67 is LSB. Rx_PWR(2) is set to
zero for “internally calibrated” devices.

68-71

4

Rx_PWR(1)

Single precision floating point calibration data, Rx optical power. Bit 7
of byte 68 is MSB, bit 0 of byte 71 is LSB. Rx_PWR(1) is set to 1 for
“internally calibrated” devices.

72-75

4

Rx_PWR(0)

Single precision floating point calibration data, Rx optical power. Bit 7
of byte 72 is MSB, bit 0 of byte 75 is LSB. Rx_PWR(0) is set to zero
for “internally calibrated” devices.

76-77

2

Tx_I(Slope)

Fixed decimal (unsigned) calibration data, laser bias current. Bit 7 of
byte 76 is MSB, bit 0 of byte 77 is LSB. Tx_I(Slope) is set to 1 for
“internally calibrated” devices.

78-79

2

Tx_I(Offset)

Fixed decimal (signed two’s complement) calibration data, laser bias
current. Bit 7 of byte 78 is MSB, bit 0 of byte 79 is LSB. Tx_I(Offset)
is set to zero for “internally calibrated” devices.

80-81

2

Tx_PWR(Slope) Fixed decimal (unsigned) calibration data, transmitter coupled output

power. Bit 7 of byte 80 is MSB, bit 0 of byte 81 is LSB.
Tx_PWR(Slope) is set to 1 for “internally calibrated” devices.

82-83

2

Tx_PWR(Offset) Fixed decimal (signed two’s complement) calibration data,

transmitter coupled output power. Bit 7 of byte 82 is MSB, bit 0 of
byte 83 is LSB. Tx_PWR(Offset) is set to zero for “internally
calibrated” devices.

84-85

2

T (Slope)

Fixed decimal (unsigned) calibration data, internal module
temperature. Bit 7 of byte 84 is MSB, bit 0 of byte 85 is LSB.
T(Slope) is set to 1 for “internally calibrated” devices.

86-87

2

T (Offset)

Fixed decimal (signed two’s complement) calibration data, internal
module temperature. Bit 7 of byte 86 is MSB, bit 0 of byte 87 is LSB.
T(Offset) is set to zero for “internally calibrated” devices.

88-89

2

V (Slope)

Fixed decimal (unsigned) calibration data, internal module supply
voltage. Bit 7 of byte 88 is MSB, bit 0 of byte 89 is LSB. V(Slope) is
set to 1 for “internally calibrated” devices.

90-91

2

V (Offset)

Fixed decimal (signed two’s complement) calibration data, internal
module supply voltage. Bit 7 of byte 90 is MSB. Bit 0 of byte 91 is
LSB. V(Offset) is set to zero for “internally calibrated” devices.

92-4

3

Reserved

Reserved

95

1

Checksum

Byte 95 contains the low order 8 bits of the sum of bytes 0 – 94.