C141-E203-01EN 5-7
Table 5.1 Physical Layer Electrical Requirements (2/2)
Nom
Min
Max
Units
Comments
Rx single-ended
impedance
40
Ohm
As seen by TDR with 100 ps (max) edge
looking into connector (20%-80%).
TDR set to produce simultaneous positive
pulses on both signals of the Rx pair.
C
ACcoupling
12
nF
Coupling capacitance value for AC
coupled TX and RX pairs
TX DC clock
frequency skew
-350
+350
ppm
Specifies the allowed ppm tolerance for
TX DC frequency variations around the
nominal 1.5GHz
TX AC clock
frequency skew
-5000
+0
ppm
Specifies the allowed ppm tolerance for
TX AC frequency variations around the
nominal 1.5GHz
TX differential
skew
20
ps
Nominal value architecture specific
Squelch
detector
threshold
100 50 200
mV
p-p
Minimum differential signal amplitude
COMRESET/C
OMINIT
detector off
threshold
175
525
ns
Detector shall reject all bursts with
spacings outside this spec
COMRESET/C
OMINIT
detector on
threshold
320
304
336
ns
Detector shall detect all bursts with
spacings meeting this period
COMRESET/C
OMINIT
transmit
spacing
320.0
310.4
329.6
ns
Differential crosspoints of last and first
edges of bursts
COMWAKE
detector off
threshold
55
175
ns
Detector shall reject all bursts with
spacings outside this spec
COMWAKE
detector on
threshold
106.7
101.3
112
ns
Detector shall detect all burst spacings
meeting this period
COMWAKE
transmit
spacing
106.7
103.5
109.9
ns
Differential crosspoints from last to first
edges of bursts
UI
OOB
646.67 686.67
ps
Operating data period during OOB burst