beautypg.com

Safety – FUJITSU TeamPoS 7000 User Manual

Page 41

background image

THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION, IS PROVIDED FOR FUJITSU CUSTOMER USE ONLY,

AND IS NOT TO BE SHARED WITH ANY THIRD PARTY WITHOUT FUJITSU’S PRIOR WRITTEN CONSENT.

TeamPoS7000_User Guide_D900000454.pdf

Revision 1.0 - March 6, 2012

Appendix - iii

Safety

Lithium-Ion Battery

Limited Power Source

Current Loading

Caution: Danger of explosion if the lithium-ion (CMOS) battery is
incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Discard used batteries according
to the manufacturer’s instructions.

Caution: The 24V powered USB port on the terminal does not meet
UL limited power source (LPS) requirements. This port is limited to
only allowing 24V Retail POS powered USB peripherals that do not
exceed a rated current of 4 Amps and are provided with a molded
plastic Fire Enclosure, Rated Min. 94V-1 or Metal enclosure.

Caution: The 24V powered Cash Drawer port on the terminal does
not meet UL limited power source (LPS) requirements. This port is
limited to only allowing 24V Retail POS peripherals that do not
exceed a rated current of .2 Amps and are provided with a molded
plastic Fire Enclosure, Rated Min. 94V-1 or Metal enclosure.

Caution: Powered USB ports are used for POS peripherals. The
current loading for each port is specified in the following table.

Port Rating

Note

12V PUSB

+12V:1.3A, +5V:0A

For LCD

12V PUSB

+12V:0.4A, +5V:0A

For VFD

12V PUSB

+12V:0.4A, +5V:0A

For VFD

24V PUSB

+24V:0.2A, +5V:0A

For Printer

USB +5V:0.5A

USB +5V:0.5A

USB

+5V:0.5A

USB (Option)

+5V:0.5A

USB (Option)

+5V:0.5A