Frymaster FLYMASTER KSCFH18E User Manual
Page 39

KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS
CHAPTER 7: TROUBLESHOOTING
7-5
7.2 Fryer Troubleshooting (cont.)
7.2.3
Computer is ON, but the
heating elements fail to
heat.
1. Ensure float safety switch is not stuck in
"down" position. Replace float safety
switch if defective.
2. If computer displays
HELP, check
high-limit thermostat (located on right
back frypot side). Replace if defective.
7.2.4
DRAIN OPEN message
remains after closing drain
valve.
1. Computer was turned OFF while
draining frypot.
2. Close drain valve. Turn computer OFF
and then ON. Computer display will
read ON.
3. Open drain valve for at least 30 seconds.
Computer display will read
DRAIN
OPEN.
4. Close drain valve. Computer display
will read
FILL.
5. Fill frypot with shortening. Press
EXIT/COOL FILTER when ready to
cook.
6. If computer message
DRAIN OPEN
remains after steps 1-4, contact
authorized Frymaster service agent.
a. Drain microswitch may be faulty.
b. Drain circuit may be suspect.
c. Computer may be suspect.