DAILY CARE

Cleaning Materials

For details about the cleaning materials, contact the
FUJITSU scanner dealer where you purchased the scan-
ner.

Cleaning Method

The ADF must be cleaned with a lint-free cloth moist-
ened with the Cleaner F1.

Locations and Cycle for Cleaning

For details on the cleaning the ADF, refer to "3.2 clean-
ing the ADF" in fi-5530C Operator’s Guide on the Setup
CD-ROM".

WARNING

When operating the scanner, the
ADF’s inside glass becomes very
hot.
Before you clean inside the scan-
ner, turn off its power and unplug
the AC adapter from the outlet. Wait
for at least 15 minutes.
Do not turn off the scanner when
you clean the Feed rollers or Eject
rollers.

Cleaning

Materials

Parts No.

Remarks

Cleaner F1

PA03950-
0352

1 bottle
Moisten a cloth with

this fluid and wipe the

scanner clean.

Lint-free dry

cloth

- Commercially available one

ATTENTION

It may take long before the cleaner
vaporizes if a large quantity is used.
When cleaning the scanner parts,
dampen a cloth with modest quantities
of the cleaner. In addition, wipe off the
cleaner completely with a soft lint-free
cloth to leave no residue on the surface
of the cleaned parts.

Part to clean

Standard Cleaning Cycle

Pad ASSY

Clean these parts after every

5,000 scans.

Pick roller

Feed rollers

Plastic rollers

Eject rollers

Sheet guides

Glass

Ultra sonic sensor

ATTENTION

The scanner must be cleaned more fre-
quently if you scan any of the following
type of sheets:

Documents of coated paper

Documents that are almost completely
covered with printed text or graphics

Chemically treated documents such
as carbonless paper

Documents containing a large amount
of calcium carbonate

Documents written by pencil

Documents on which the toner is not
fused sufficiently.