3-3

Table 3.1

Zone layout and track capacity

Cylinder

Zone

MAS3735NC/NP

MAS3367NC/NP

MAS3184NC/NP

Byte/track

Sector/track

0

0 – 1,848

360,960

705

1

1,849 – 3,697

360,960

705

2

3,698 – 5,546

360,960

705

3

5,547 – 7,395

360,960

705

4

7,396 – 9,244

360,960

705

5

9,245 – 11,093

360,960

705

6

11,094 – 12,298

359,424

702

7

12,299 – 14,315

350,208

684

8

14,316 – 16,080

340,992

666

9

16,081 – 17,173

336,384

657

10

17,174 – 19,330

331,776

648

11

19,331 – 20,255

322,560

630

12

20,256 – 21,404

317,952

621

13

21,405 – 22,469

313,344

612

14

22,470 – 24,514

304,128

594

15

24,515 – 26,195

294,912

576

16

21,196 – 26,840

290,304

567

17

26,841 – 27,093

26,841 – 27,149

26,841 – 27,205

285,696

558

Note: When the logical data block length is 512 bytes, the sector/track capacity indicates above amount

(1)

User space

The user space is a storage area for user data. The data format on the user space (the length of data
block and the number of data blocks) can be specified with the MODE SELECT or MODE
SELECT EXTENDED command.

The default value of cylinders in the user space is MAS3735NC/NP = 27,094, MAS3367NC/NP =
27,150, MAS3184NC/NP = 27,206. These also equal the maximum cylinders number for each
series. The user can also specify the number of logical data blocks to be placed in the user space
with the MODE SELECT or MODE SELECT EXTENDED command. When the number of
logical data blocks is specified, as many cylinders as required to place the specified data blocks are
allocated in the user space.