beautypg.com

3 environmental specifications – FUJITSU C141-E185-01EN MAS3184NC/NP User Manual

Page 30

background image

2-4

C141-E185

2.1.3

Environmental specifications

Table 2.3 lists environmental and power requirements.

Table 2.3

Environmental/power requirements

Specification

Item

MAS3735NC/NP

MAS3367NC/NP

MAS3184NC/NP

Operating

5 to 55°C

Non-operating

–40 to 70°C

Transport
(within a week)

–40 to 70°C

DE surface temperature
at operating

5 to 60°C

Temperature
(*1)

Gradient

15°C/h or less

Operating

5 to 95%RH

Non operating

5 to 95%RH

Transport
(within a week)

5 to 95%RH

Relative
humidity

Maximum wet bulb
temperature

29°C (no condensation)

Operating (*3)

0.3 mm (5 to 20Hz)/9.8 m/s

2

(1G) (20 to 300 Hz) or less

Non-operating (*4)

3.1 mm (5 to 20Hz)/49m/s

2

(5G) (20 to 300Hz) or less

Vibration
(*2)

Transport (packaged)

3.1 mm (5 to 20Hz)/49m/s

2

(5G) (20 to 300Hz) or less

Operating

637.4m/s

2

(65G) (2 ms)

Non-operating

2451.7m/s

2

(250G) (2 ms)

Shock (*2)

Transport (packaged)

2451.7m/s

2

(250G) (2 ms)

Operating

–300 m to 3,000 m

Altitute
(above sea
level)

Non-operating

–300 m to 12,000 m

Ready
(Average)

0.75 A

0.52 A

0.42A

Peak within
100

µ

s at

spin-up

3.0 A

+12 VDC
±5%

Random
W/R
(about 80
IOPS)

1.0 A

Ready

0.5 A

+5 VDC
±5% (*6)

Random
W/R
(about 80
IOPS)

1.0 A

Power
requirements
Input power
(*5)

Ripple (*7)

+5 V/+12 V 250 mVp-p

(*1)

For detail condition, see Section 4.1.

(*2)

Vibration applied to the drive is measured at near the mounting screw hole on the frame as much
as possible.

(*3)

At random seek write/read and default on retry setting with log sweep vibration.