TROUbLESHOOTING

Continued

OBSERVED PROBLEM

Heater produces unwanted
odors

Heater shuts off in use (ODS
operates)

Gas odor even when control
knob is in OFF position

Gas odor during combustion

POSSIBLE CAUSE

1. Heater burning vapors from

paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPOR-
TANT
statement above)

2. Gas leak. See Warning

statement at top of page

1. Not enough fresh air is

available

2. Low line pressure

3. O D S / p i l o t i s p a r t i a l l y

clogged

1. Gas leak. See Warning

statement at top of page

2. Control valve defective

1. Foreign matter between

control valve and burner

2. Gas leak. See Warning

statement at top of page

REMEDY

1. Open window and venti-

late room. Stop using odor
causing products while
heater is running

2. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 15)

1. Open window and/or door

for ventilation

2. Contact local natural or

propane/LP gas company

3. Clean ODS/pilot (see

Cleaning and Maintenance,
page 23)

1. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 15)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 15)

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup-
plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc.,
create fumes. These fumes may mix with combustion air and create odors. These odors will
disappear over time.