Installation – FMI FLAME-MAX FVFM27NR User Manual

Page 13

background image

www.fmiproducts.com

121353-01H

13

INSTALLATION

Continued

Area of Various Standard Round Flues

Diameter

Area

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney Height

Minimum permanent

Flue Opening

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Damper Clamp

Damper
Clamp

Damper

Damper

Masonry Fireplace

Manufactured

Fireplace

Figure 10 - Attaching Damper Clamp

INSTALLING HEATER BASE
ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: You must secure

this heater to fireplace floor. If

not, heater will move when you

adjust controls. Moving heater

may cause a gas leak.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access to

heater control panel. This will in-

sure adequate air flow and guard

against sooting and controls be-

ing damaged. Raise fireplace floor

with noncombustible material.

Make sure material is secure.

CAUTION: Do not pick up

heater base assembly by the

burner. This could damage

heater. Only handle base as-

sembly by grates.

IMPORTANT: Make sure the heater burner
is level. If heater is not level, heater will not
work properly.

Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (provided)

(if allowed by local codes)

• sealant (resistant to propane/LP gas, not

provided)

• electric drill with 3/16" drill bit (metal or

masonry as applicable)

• flathead screwdriver
1. Apply pipe joint sealant lightly to male

threads of the fitting to be threaded into
gas control. Connect approved flexible gas
hose (provided for VYM models only) to
gas control fitting in heater (see Figure 11).
IMPORTANT: Hold gas fitting with wrench
when connecting flexible gas hose.

2. Locate 2 masonry screws in hardware

package.

See chart below for minimum permanent flue
opening you must provide. Attach damper
clamp so the minimum permanent flue open-
ing will be maintained at all times.

Fitting

Flexible Gas Hose
(Provided for VYM
models only) (if
allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose

to Heater