WARNING:

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

Figure 16

Figure 15

Figure 14

Figure 12

Figure 13

Remove base unit and cover from box.

3.

Apply supplied Duct Seal Kit according to instructions included in kit.

4.

(See Figure 12)
Determine whether to use flat or angled bracket. (Refer to Bulb

5.

Mounting Bracket Selection)

Flat Bracket Installation

a.

i. Remove the two hex nuts and flat bracket from included bagged

hardware.
ii. Install the flat bracket and secure to the unit base with the hex

nuts provided. (See Figure 13)

Angled Bracket Installation

b.

NOTE:

For angled bracket mounting, refer to specifications outlined

by Charts A & B for mounting distances in the Angled Lamp Mounting

Bracket Specifications.

i. Remove the two hex nuts and angled bracket from included

bagged hardware.

ii. Install the angled bracket and secure to the unit base with the

hex nuts provided. (See Figure 14)

NOTE:

Be sure to note location of lamp hole in bracket relative to unit

base.

Mount the unit base to the duct using the four mounting screws

6.

provided. (See Figure 15)
Remove tag and alcohol wipe from lamp. Wipe off lamp being sure

7.

not to touch lamp with bare hands. The oils in your hands cause a

reduction in lamp output.
Insert lamp through the hole until lamp cannot be inserted any further.

8.

(See Figure 16)