Page 37

27
2.2.1 Synchronizing Transmission with Echo Sounder or Other
Sonar
To synchronize transmission of the CH-250 with an echo sounder or other type of sonar,
connect it as shown below.
Transceiver unit
06P0240
J3
KPI
EXT_SW
GND
3
5
6
KP OUT
+5V to 15V
GND
Sonar, E/S
TRX clamp
NH6P (local supply)
Vinyl wire (local supply)
AWG22-26
3 to 15V
possitive
Connection of transceiver unit to other sonar
Menu setting
1. Press the [MENU] key to display the user menu.
2. Operate the cursor pad to select COM1 at the top of menu display.
OFF
TX POWER
MAX
PULSELENGTH
LONG
TX RATE
10
INT REJECT
AGC
OFF
: SELECT
: CHANGE
MENU: END
REPLACE ONE OF ANY COLORS AMONG COLOR BAR WITH WHITE.(OFF)
MENU
COM1
COM2 HORZ VERT ES PRESET SYS
AUDIO LEVEL
0
User menu (COMN)
3. Press the [] to select TX RATE.
4. Press the [] to display the setting window.