2 accessing fryers for servicing – Frymaster 2424G User Manual
Page 11
24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-5
Safety Components
All 24G Series Flatbottom gas fryers are equipped with a high-limit thermostat. In the event that the
fryer fails to properly control the oil temperature, the high-limit thermostat prevents the fryer from
overheating to flash point. The high-limit thermostat acts as a normally closed power switch that
opens when exposed to temperatures above 410°F [(210°C)- CE] to 435°F [(224°C)- Non-CE]. CE
and non-CE high-limits are not interchangeable.
Frying systems with built-in filtration are equipped with drain microswitches that disable the fryer if
the drain valves are not completely closed. Opening a drain valve (i.e. filtering or draining the fryer)
automatically opens the reset switch circuit. The drain valve must be fully closed prior to resetting
the safety switch.
1.2 Accessing Fryers for Servicing
DANGER
Moving a fryer filled with cooking oil/shortening may cause spilling or splattering of
the hot liquid. Follow the draining instructions included with the fryer before
attempting to relocate a fryer for servicing.
NOTE: Perform the following only if the fryer cannot be serviced in its installed location. Some of
the following service procedures require the fryer to be connected to the gas and/or electrical supply.
1. Shut off the gas supply to the unit. Unplug the power cords. Remove any attached restraining
devices.
2. Disconnect the unit from the gas supply.
3. Relocate the fryer for service accessibility.
4. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and
plug in the electrical cords.