Technical Data for CE Marked Products
Nominal Heat Input:
Natural (I
2H
) = 35,2 KW (120,100 Btu/h)
(Net)
Liquid Propane (I
3P
) = 35,2 KW (120,100 Btu/h)
Nominal Heat Input:
Natural (I
2H
) = 39,1 KW (133,400 Btu/h)
(Gross)
Liquid Propane (I
3P
) = 38,3 KW (130,700 Btu/h)
Supply Pressure:
Natural (I
2H
) = 20 mbar
Liquid Propane (I
3P
) = 37 mbar
Liquid Propane (I
3P
) = 50 mbar
Test Point Pressure:
Natural (I
2H
) = 8,7 mbar
Liquid Propane (I
3P
) = 25 mbar
Injector Size:
Natural (I
2H
) = 3,18 mm
Liquid Propane (I
3P
) = 1,91 mm
This appliance must be installed in accordance with the manufacturers instructions and the regulations in
force and only used in a suitable ventilated location. Read the instructions fully before installing or
using the appliance.
Datos Tecnicos Para Products CE
Consumo Calorico Nominal:
Gas Natural (I
2H
) = 35,2 KW (120,100 Btu/h)
(Neto)
Propano Licuado (I
3P
) = 35,2 KW (120,100 Btu/h)
Consumo Calorico Nominal:
Gas Natural (I
2H
) = 39,1 KW (133,400 Btu/h)
(Bruto)
Propano Licuado (I
3P
) = 38,3 KW (130,700 Btu/h)
Presion De Alimentacion:
Gas Natural (I
2H
) = 20 mbar
Propano Licuado (I
3P
) = 37 mbar
Propano Licuado (I
3P
) = 50 mbar
Presion En Ez Punto De Prueba: Gas Natural (I
2H
) = 8,7 mbar
Propano Licuado (I
3P
) = 25 mbar
Diámetro Boquilla:
Gas Natural (I
2H
) = 3,18 mm
Propano Licuado (I
3P
) = 1,91 mm
Este equipo debe instalarse únicamente en un recinto adecuadameute ventilado y conforme a las
indicaciones del fabricante y a las normas vigentes. Lea completamente las instrucciones antes de
instalar o usar este equipo.