beautypg.com

Summary of audible notification, Alpha display keypads) – Honeywell VISTA-128BP User Manual

Page 73

background image

– 73 –

Summary Of Audible Notification

(Alpha Display Keypads)

SOUND CAUSE

DISPLAY

LOUD,

INTERRUPTED*

Keypad

&

External

FIRE ALARM

FIRE is displayed; descriptor of zone in alarm is

displayed.

LOUD,

CONTINUOUS*

Keypad

&

External

BURGLARY/AUDIBLE EMERGENCY

ALARM

ALARM is displayed; descriptor of zone in alarm is

also displayed.

ONE SHORT BEEP
(not

repeated)

Keypad only

a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT

WITH AN OPEN ZONE.

c. BYPASS VERIFY

a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection

zone is displayed.

c. Numbers and descriptors of the bypassed

protection zones are displayed (One beep is heard
for each zone displayed). Subsequently, the
following is displayed: DISARMED BYPASS Ready
to Arm

ONE SHORT BEEP
(once

every

15

sec.) Keypad only

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

TWO SHORT BEEPS
(once every 5 sec.)

Keypad only

SYSTEM IS ABOUT TO

AUTOMATICALLY EXIT TEST
MODE

Opened Zone identifications will appear.

ONE BEEP
(every 60 sec.)

Keypad only

LOW BATTERY AT A TRANSMITTER

LO BAT displayed with description of transmitter.

TWO SHORT BEEPS
Keypad

only

ARM AWAY OR MAXIMUM

ARMED AWAY or ARMED MAXIMUM is displayed.

Red ARMED indicator is lit.

THREE SHORT

BEEPS

Keypad

only

a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYSTEM

IS IN CHIME MODE.

c. ENTRY WARNING**

a. ARMED STAY ZONE BYPASSED or ARMED

INSTANT ZONE BYPASSED is displayed. Red
ARMED indicator is lit.

b. CHIME displayed, descriptor of open protection

zone will be displayed if the [

✱] key is pressed.

c. DISARM SYSTEM OR ALARM WILL OCCUR is

displayed.

RAPID BEEPING
Keypad

only

a. TROUBLE
b. AC POWER LOSS ALERT***
c. MEMORY OF ALARM

a. CHECK displayed. Descriptor of troubled protection

zone is displayed.

b. AC LOSS displayed (may alternate with other display

that may be present).

c. FIRE or ALARM is displayed; descriptor of zone in

alarm is displayed.

SLOW BEEPING
Keypad

only

a. ENTRY DELAY WARNING**
b. EXIT DELAY WARNING
(if

programmed)

a. DISARM SYSTEM OR ALARM WILL OCCUR is

displayed. Exceeding the delay time without
disarming causes alarm.

b. ARMED AWAY or ARMED MAXIMUM is displayed

along with You May Exit Now

*

If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**

Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

*** Loss

of

system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power

only).