Using #77 instant activation mode – Honeywell VISTA-128BP User Manual
Page 57
– 57 –
Using #77 Instant Activation Mode
The #77 Instant Activation Mode is used to activate outputs, bypass zones,
etc. immediately upon exiting the #77 Mode. The actions that may be
activated are relay commands, arm/disarm commands, zone bypassing
commands, and open/close access conditions.
Relay Commands
Action Code Action
Specifier
01
Relay On
Relay #
02
Relay Off
Relay #
03
Relay Close for 2 seconds
Relay #
04
Relay Close XX minutes
✳ Relay
#
05
Relay Close YY seconds
✳ Relay
#
06
Relay Group On
Relay Group #
07
Relay Group Off
Relay Group #
08
Relay Group Close for 2 seconds
Relay Group #
09
Relay Group Close XX minutes
✳
Relay Group #
10
Relay Group Close YY seconds
✳
Relay Group #
✳ Check with your installer for the amount of time.
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices
for automatic arming and disarming functions.
"During" can be used to arm or disarm the control for a specific time only.
For example, if "during" is selected with Arm-STAY, the system will
automatically Arm-STAY at the beginning of the window and automatically
disarm at the end of the window.
Action Code Action
Specifier
20
Arm-STAY
Partition(s)
21
Arm AWAY
Partition(s)
22
Disarm
Partition(s)
23
Force Arm STAY (Auto-bypass faulted zns)
Partition(s)
24
Force Arm AWAY (Auto-bypass faulted zns)
Partition(s)
25 Arm
INSTANT
Partition(s)
26 Arm
MAXIMUM
Partition(s)