Operation – Harman Stove Company PB 105 User Manual
Page 30

30
3-90-07205R19_05/13
Operation
NOTE: Stirring the starting gel into the pellets usually
allows the fire to become established quicker.
CAUTION: A vapor flash could occur if too much time
is allowed to pass before lighting the starting gel.
CAUTION: Care must be taken not to get starting gel
on your hands or clothing. Serious burns could occur
during the lighting process.
CAUTION: Never try to apply more starting gel to an
already burning fire, or a fire with smoldering pellets.
“NeVeR USe GASOlINe, GASOlINe-TYPe
lANTeRN FUel, KeROSeNe, CHARCOAl lIGHTeR
FlUId, OR SIMIlAR lIQUIdS TO START OR
“FReSHeN UP “ A FIRe IN THIS APPlIANCe. KeeP
All SUCH lIQUIdS Well AWAY FROM THe UNIT
WHIle IN USe”.
Fig. 15
11. Apply starting gel as shown in Fig.15
12. light The Starting Gel With A Match.
13. Close The doors
The fire will light and the control will adjust the fire to the
proper level according to the MAX TEMP dial setting.
Fig. 16
NOTICe: When burning the boiler in the manual
ignition mode, there must be an overheat dump
zone incorporated into the plumbing system.
If heating demand stops during manual operation, the
control will take the unit to low burn. If no heat is used
during this time, the water temperature will continue to
rise. When the temperature gets too high, the feeder will
be turned off and the fire will go out. This will require a
manual re-start of the system. (see page 23 “7 Blinks”)
Solid-fuel burning appliances need to be cleaned
frequently because soot, creosote, and ash may
accumulate.
If you suspect a chimney/vent pipe fire
do the following:
1. Call the fire department.
2. Remove fuel from the burn pot using the burnpot
scraping tool to scrape the pellets into the ash pan.
3. Remove the ash pan from the unit and take outside.
Do not place ash pan on a combustible material.
4. Turn off circuit breaker at unit.
5. Do not use the unit until a qualified person has
inspected your appliance and venting.