beautypg.com

Configuring static pw redundancy, Configuring ldp pw redundancy – H3C Technologies H3C S6800 Series Switches User Manual

Page 347

background image

334

Manually perform a PW switchover.

Configuring static PW redundancy

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter cross-connect group

view.

xconnect-group group-name

N/A

3.

Enter cross-connect view.

connection connection-name N/A

4.

(Optional.) Specify whether
to switch traffic from the

backup PW to the primary

PW when the primary PW
recovers, and set the wait

time for the switchover.

revertive { wtr wtr-time | never }

By default, traffic is immediately
switched back from the backup

PW to the primary PW when the

primary PW recovers.

5.

Enter cross-connect PW view.

peer ip-address pw-id pw-id
[ in-label label-value out-label

label-value ] [ pw-class class-name
| tunnel-policy tunnel-policy-name ]

*

N/A

6.

Configure a backup

cross-connect PW and enter
backup cross-connect PW

view.

backup-peer ip-address pw-id
pw-id in-label label-value out-label

label-value [ pw-class class-name |
tunnel-policy tunnel-policy-name ] *

By default, no backup PW is
configured.

7.

Return to user view.

return

N/A

8.

Manually perform a PW

switchover.

l2vpn switchover peer ip-address
pw-id pw-id

N/A

Configuring LDP PW redundancy

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter cross-connect group

view.

xconnect-group group-name

N/A

3.

Enter cross-connect view.

connection connection-name N/A

4.

(Optional.) Specify whether
to switch traffic from the

backup PW to the primary

PW when the primary PW
recovers, and set the wait

time for the switchover.

revertive { wtr wtr-time | never }

By default, traffic is immediately
switched back from the backup

PW to the primary PW when the

primary PW recovers.

5.

Enter cross-connect PW view.

peer ip-address pw-id pw-id
[ pw-class class-name |

tunnel-policy tunnel-policy-name ] *

N/A